AC Power Connection
• Main power supply selected should have suitable grounding means
and be UL approved.
• Connections in to the Power supply must be made by a qualified electrician
who should as a minimum fit a GFCI.
Output voltage must not exceed 30V and total power supplied to circuit must
be less than 300Watts, for cable max amperage see table below:
Wire Gauge (AWG)
18
16
14
12
10
SI equivalent, mm
2
sectional area
0.82
1.3
2.1
3.3
5.3
Ampacity (amperes)
7 amps (10) 10 amps (13)
15 amps (18) 20 amps (25) 25 amps (30)
• Voltage drop will occur and must be considered in the design, please contact
AVID Labs
®
with design installation questions or for additional cable lengths.
• Connections must be made when mains power is disconnected.
• Connections should be made into a suitably rated NEMA box by a qualified
electrician. Connections to the box should be made outside of any water.
• The minimum cable length from the fixture in to the box should be 2', the
maximum length is 6', where an AVID Labs
®
approved sealed connector is
placed in-line from the unit to NEMA box. The connector should be checked
to ensure it is properly connected. Any connections/disconnection must be
made outside of the water.
• All wiring must meet national and local electrical code.
ADDITIONAL LOW VOLTAGE CABLES
To order additional cable lengths contact AVID Labs
®
or visit AVIDLabs.com.
Please ensure your design has been checked by a qualified electrician prior
to installation.
Warranty
Items are covered for defects in materials and workmanship for five years,
including repair parts and repair labor on defective item, from date of the
manufacturer invoice. The warranty covers freight for 30 days after initial purchase.
The manufacturer does not cover any other loss resulting from product failure.
Products being returned for warranty repair must display the original serial number.
Removal of the serial number voids the product’s limited warranty.
Low Voltage Connections