FUNCTIONAL ADVICE

CONTROL

LED LIFETIME ADVICE

1.  Do not hot switch connections, ensure power is off when  

connecting supplies.

2.  Check supply voltage. If unsure contact licensed electrician  

and/or AVID Labs

®

3.  Product must be checked by a licensed electrician prior  

to commission. 

4.  Where code requires, ducting may be ran to the rear of the unit.  

The ducting should be installed by a licensed electrician.

LED lifetime is determined by the gradually declining brightness 
of an LED over time where, the point of 70% brightness reduction 
marks the defined end of its lifetime. The driving factor of this 
effect is the heat that the chip inside the unit is exposed to. While 
an LED may reach 100,000 hours under ideal circumstances, the 
real-world lifetime may be 60,000 hours. This may be less if  
the LED is exposed to excessive heat, which can be caused by 
continuously running the LED inside this device at full power  
and operating the unit in high environmental temperatures. If  
improving the lifetime of the LED is a concern, keeping the  
operating temperature lower is advised. This may include forced 
air external cooling and/or the reduction of overall intensity.

2.

 

RGBW - 7 Conductor cable,

 

Orange Power 24VDC +,

 

Blue Power 24DC-,

 

Green DMX +,

 

White DMX +,

 

Red DMX-,

 

Black DMX -,

 

Drain Wire DMX common.

Minimum voltage for the product is 24V.       

Standard Fixed Color - the unit has a third line in allowing a  
PWM signal to be send to the internal drive. This signal controls  
the dimming of the driver. The driver will run at full power despite 
voltage drops without a signal. Minimum voltage for the product  
is 12V.      

1. 

Summary of Contents for AVERE 3 Wash

Page 1: ...Unique lighting solutions 488649...

Page 2: ...energized Bronze version only DO NOT use in water intended for swimming wading immersion or bathing All installer completed cable connections must be located outside of pond or fountain Low voltage c...

Page 3: ...fety Information 3 8 General Advice 4 Protection from Eye Injury 4 Protection from Electric Shock 5 6 Protection from Fire 6 Protection from Injury And Damage 7 Environmental Advice 7 Functional Advic...

Page 4: ...f use flexibility build quality and overall functionality make us confident you made the right choice in lighting fixtures Our lighting experts and engineers will consult with you on ways to use our s...

Page 5: ...hazard Equipment must be properly grounded MISE EN GARDE Risque d lectrocution quipement doit tre correctement mise la terre WARNING Hot surface Risk of skin burn or skin irritation MISE EN GARDE Sur...

Page 6: ...the unit mechanically and or electrically 1 Warning Depending on the configuration of the device this device reaches the limits of IEC EN62471 Group 3 depending upon exposure and chip type Avertissem...

Page 7: ...outes les connexions de c bles achev es par l installateur doivent tre situ es l ext rieur de l tang ou de la fontaine Unit de bronze seulement 4 Low voltage circuit must be supplied by a power unit m...

Page 8: ...tres personnes non autoris es L UNIT EST NON UTILISABLE PROTECTION FROM FIRE 1 When possible avoid placing the unit near sources of heat Dans la mesure du possible vitez de placer l appareil proximit...

Page 9: ...e surcharge montage suivez le gr ement applicable r gles et r glements pour le gr ement de s curit 3 All bolts should be checked for a tight fit prior to use In addition every 6 months the bolts shoul...

Page 10: ...ED may reach 100 000 hours under ideal circumstances the real world lifetime may be 60 000 hours This may be less if the LED is exposed to excessive heat which can be caused by continuously running th...

Page 11: ...BW Power Consumption 12 5W Max Submersion Depth 1 0m Max Bronze only Power Cord 6 120V SJEOW Outdoor Cable Dimensions WxDxH 3 00 x 2 81 x 5 00 76 2mm x 71 34mm x 127mm Mounting Hole 17 32 or Knuckle M...

Page 12: ...hreaded rod should have sufficient chemical and corrosion resistance for the application 2 Knuckle mount For installations above water only A knuckle mount with ground spike can be used Electrical con...

Page 13: ...be inspected by a trained person Tous les boulons shoulderstand tre v rifi s pour un ajustement serr avant utilisation En outre tous les 6 mois les boulons doivent tre inspect s par une personne qual...

Page 14: ...du montage retrait ou entretien de l appareil The installation should be inspected every 6 months or more frequently if deemed necessary Inspection should be performed by a skilled person to ensure sa...

Page 15: ...de of any water The minimum cable length from the fixture in to the box should be 2 the maximum length is 6 where an AVID Labs approved sealed connector is placed in line from the unit to NEMA box The...