ZM400 Series Indicators Service Manual
85
7.3
NCI commands
7.3 NCI commands
Refer to the NCI Standard Document (AWTX Control Document SCP-01) for
complete details on NCI command protocol. This is available on the www.averyweigh-
tronix.com website. Search for SCP-01 on the website.
W <Cr>
Weight request
Returns decimal weight, units and status
S <Cr>
Status request
Returns status.
Z <Cr>
Zero request
Scale is Zeroed and returns scale status.
H <Cr>
High Resolution Weight request
Returns decimal wt in 10x or x100 resolution with units and status.
For x100 resolution set the associated PROT > ATTR > ENQ menu value to 100.
For all other values the H command will return x10 resolution
U <Cr>
Units request
Changes unit of measure and then returns decimal weight in the new units with
status.
M <Cr>
Metrology Raw Counts request
Returns normalized raw counts and scale status.
T <Cr>
Tare request
Scale is Tared and returns scale status.
all else
Unrecognized command
Returns <Cr> ? <Lf>
for status byte informatlon.
If the
PROT > ATTR > ENQ
menu value is set to 100, to increase resolution by 100, you
may add a 2 or 3 to the command to return a 2 or 3 character status byte. For
example: 102 will increase resolution by 100 and return a 2 character status byte.