15
There are six preset serial print formats. Choose the one you want to use
during configuration of the scale. See the
Service Manual
for configuration
instructions. The formats are described below.
Abbreviations:
CR = carriage return
LF = line feed
SP = space
U = units character
W = weight character
C = count character
T = tare character
G = gross weight character
P = piece weight character
I = weight type identifier (G for gross, T for tare and N for net)
Net weight only:
WWWW.WW<CR><LF>
Net weight with units:
WWWW.WW<SP>UU<CR><LF>
GTN with units:
'G'<SP>GGGG.GG<SP>UU<CR><LF>
'T'<SP>TTTT.TT<SP>UU<CR><LF>
'N'<SP>WWWW.WW<SP>UU<CR><LF>
Displayed weight with identifier:
I<SP>WWWW.WW<CR><LF>
In Count Mode:
N<SP>CCCC<SP>PCS<CR><LF>
In Weigh Mode:
I<SP>WWWW.WW<SP>UU<CR><LF>
Preset Print Formats
Imp Printer Format 0
Imp Printer Format 1
Imp Printer Format 2
Imp Printer Format 3
If the scale is in count mode,
displayed weight formats will
send weight, not count.
Imp Printer Format 4