d) Switch on the projector with “Power ON” button located at the projector body or it’s remote transmiter.       
e) LED1 indicator will blink 3 times and douse to confirm the power consumption level was recognized and 

                 memorized.

    Beta control system is ready for usa as soon as the programming procedure is finished.

4. Control system operation

4.1 Automatic operation

  

        - Press “POWER” button at the projector’s remote control transmitter or at the projector itself, projector lamp will light- 
          on. BETA control system will switch on motors of connected devices (i.e.  projection screen and projector lift). 
          Motors will stop automatically as soon as the bottom stop points will be reached.
        - Press  “POWER” button at the projector’s remote control transmitter or at the projector itself, projector lamp will light 
          off. BETA control system will switch on motors of connected devices (i.e.  projection screen and projector lift). Motors 
          will stop automatically as soon as the upper stop points will be reached.

4.2 Manual operation

Manual control of devices conected to the BETA control system is possible with the optional wall control switch (original 

screen/lift wall control switch) connected to the dedicated termina.

  - Push button “

”,  BETA control system will switch on motors of connected devices (i.e.  projection screen and 

    projector lift). Motors will stop automatically as soon as the bottom stop points will be reached.

       - Push button “



”, BETA control system will switch on motors of connected devices (i.e.  projection screen and 

         projector lift). Motors will stop automatically as soon as the upper stop points will be reached.

4.2 Control system maintenance

 

BETA control system do not require periodical service maintenance. Clean dust from the control unit case with dry soft 

cloths.  If needed use moisturized cloth with soft detergent to remove stains. After stain removal dry the cleaned surface 
with cloth carefully.

4.3 Before calling the service

!!!CAUTION!!!
    Programming procedure must be performed each time attached projector is replaced with an other unit/model 

Avers BETA control system provides automatic and/or manual control of 2 electric devices for example Avers projection 

screen (models without integrated control system) and Avers Prolift projector lift.  

At other cases please contact service.

Symptoms

Reasons

Remedy 

Control system do not react to 
projector “Power On” action

Projector power cord is not plugged into the 
BETA power outlet.

Power consumption from the outlet at the 
Trigger Transmitter is too low.

Plug in projector power cable to the BETA 
power outlet.

Re-programm BETA control system with the 
projector.

Summary of Contents for BETA

Page 1: ...BETA 2 device control system trigered by projector power consumption User s manual Read these instructions carefully before operating the screen ...

Page 2: ...p the remote control transmitter out of reach of children SAFETY INFORMATION NOTICE Important safety information Follow the instructions described in the operating manual for safety reasons After reading the manual please store it in a safe place just in case you need it in the future NOTICE THE DEVICE HAVE TO BE EARTHED WARNING 1 Disconnect the device from the power supply if it will not be used ...

Page 3: ...reen is completely rolled in out It will help to avoid injuries caused with moving screen All installation work should be carried out by the qualified technician Improper installation can cause device damage or health breakdown Do not do anything that may damage the power cables Operation of the control system with damaged power cords can result with electric shock electric short circuit and fire ...

Page 4: ...Connection cable length 145cm Control votage 220 240V AC 50Hz Max control current 1 5A Programmable power consumption level triggering the control unit 3 Control system installation 3 1 Installation precautions Installation work should be carried out by a qualified technician in accordance with the instructions described below Fixed installation of the control system should be done with use of the...

Page 5: ... the screen power line during installation work Manual wall steering switch should be installed at the place meeting the following conditions a installation150 180cm above the floor level b the screen should be visible by the wall switch operator during the screen operation c wall switch operator cannot stay in reach of any of the screen s moving parts during the screen operation Connect screen ca...

Page 6: ...button BETA control system will switch on motors of connected devices i e projection screen and projector lift Motors will stop automatically as soon as the bottom stop points will be reached Push button BETA control system will switch on motors of connected devices i e projection screen and projector lift Motors will stop automatically as soon as the upper stop points will be reached 4 2 Control ...

Page 7: ...failures caused by the usage of the control system against the rules described in operation manual b the failures caused by improper storage or transportation c mechanical defects of the control system other than mentioned at point 3 d damages caused with overvoltage at power network e deinstallation and reinstallation of the screen 5 Avers Screens Service department will remove all defects within...

Page 8: ... correctly will help to save valuable resources and prevent any potentialnegative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Wersja 20 05 2012 CAUTION Check the holes printed at the template match the location of fixing points at the con...

Reviews: