www.avenview.com
7
2.2 Absolute Maximum Ratings
Parameter
Symbol
Minimum Maximum Units
Power Supply
VCC
-0.3
5.5 V
Operating Temperature
VOT
0
50 °C
Storage Temperature
VST
-20
70 °C
Relative Humidity
HRH
10
80 RH
2.3 Signal Pin Assignment
Transmitter / Receiver
Pin
Signal Assignment
Pin
Signal Assignment
1
T.M.D.S. Data2+
11
T.M.D.S Clock Shield
2
T.M.D.S. Data2 Shield
12
T.M.D.S Clock -
3
T.M.D.S. Data2-
13
CEC
4
T.M.D.S. Data1+
14
No Connect
5
T.M.D.S. Data1 Shield
15
SCL
6
T.M.D.S. Data1-
16
DSA
7
T.M.D.S. Data0+
17
DDC/CEC Ground
8
T.M.D.S. Data1 Shield
18
+5V Power
9
T.M.D.S. Data0-
19
Hot Plug Detect
10
T.M.D.S Clock +
Stresses greater than those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. This is a stress rating only and functional operation of
the device at these or any other conditions above those indicated in the operations section
for extended periods of time may affect reliability.