The maximum length of the push/pull cable must not
exceed 3m. Do not bend the cable tighter than 200mm.
Fig. 4:
Installation in the engine room
W
With 12-V-systems, the connection point of the power
supply may be 5m away at maximum, 10m with 24-V-
systems. Even under full load of all consumers connected,
the power at the connection point must not fall below -25%.
Prepare the assembly of the Marex ECS Actuator:
1.
Make sure that all Marex ECS components are powered off
before installing the Marex ECS Actuator.
Table 7:
Max. cable lengths
Power 12V
5m max.
Power 24V
10m max.
Propulsion
250m max. total length
Push/Pull (mechanical)
3m max.
max. 3 m