Page 13
TEST ARRANGEMENT DIAGRAM
Notes:
1.
AVENTICS TASKMASTER
®
timing volume, Part Number R434002899 (Old Part No.TM -058887-
00225), can be used for the volumes indicated.
2.
The supply air lines to the valves and delivery lines must be full size as shown. Line length must
not exceed 3 ft. (1 meter) between the supply valve and “IN” port, and between the “OUT” port
and delivery test volume(s). The piping connections must have zero leakage, and must not
restrict the flow. If quick couplers are used, be sure they are full flow or oversize.
3.
It is recommended that as large of a gauge as practical be used on the delivery lines. A 6” gauge
is recommended.
Adjustable CAM Roller
“A” Dimension
See Identity Schedule
Page 5 for “A” Dimension
IN
OUT
PD-020031-00091
RECOMMENDED:
AVENTICS New P/N R432016359
(Old P/N PR-007816-00010)
CLEAN, DRY, CHEMICAL FREE AIR
SUPPLY 200 PSIG MAXIMUM (OR
20 PSIG ABOVE MAXIMUM DELIVERY
PRESSURE OF ANY VALVE TESTED).
PRESSURE
GAGE
1/4” PIPE SCHEDULE 40
OR
3/8” O.D. TUBING
OR
#6 SINGLE BRAID HOSE
CHOKE PLUG .032
OPTIONAL:
REQUIRED FOR LOW SPRING
RANGE VALVES ONLY.
225 in
3
225 in
3