To set up your AVE Vaperzia smoke machine follow the below steps;
1.
Unpack machine carefully. Ensure you have received all the included components and there
has been no damage or leakage in transport.
2.
Ensure the machines hose is threaded through the additional cap included and brass filter is
attached to inlet hose.
3.
Undo the cap on top of the liquid reservoir and attach the additional cap with hose, making
sure the hose and filter are completely immersed in the liquid.
4.
Plug both the remote control and the power lead into the unit, and switch on.
5.
Wait for the machine to complete its designated heat-up time
6.
Once heat-up time is complete the remote control will indicate the unit is ready, press and
hold down manual button to being priming.
During priming,
the Vaperiza will make a rattling noise until the fluid has been drawn into the
machine. Keep the button depressed until the rattling subsides and a steady jet of fog is being
produced.
This process can take 1 – 2 minutes; the machine may go through re-heat cycles where it stops
momentarily to re-heat.
Refilling the Machine
The Vaperiza is fitted with an internal 1.2L fluid reservoir, which will need to be re-filled from time to
time.
To refill the machine
1.
Ensure the power cable is not connected and the machine is cool.
2.
Open the fluid reservoir and move the feeding tube and cap to 1 side.
3.
Using a funnel to prevent spilling, carefully refill the machine using the gauge on the rear.
DO NOT OVERFILL THE MACHINE
4.
Place the feeding tube back in the machine ensuring it is submerged in the fluid, and reseal
the reservoir cap.