The cash register side has an external power supply connec-
tor to use a standard 2.1 x 5.5 mm DC Coax power connector 
and unregulated 12VDC should be used. However the Op-
to232 has jumpers to select using DTR (Pin4) and DSR (Pin6) 
to power to the Opto232 if the cash register has this ability. 
However, if the cash register is just using its TXD signal to 
send data to the VSI-Pro no power supply or power connec-
tion is required. This power source is only required if data from 
the VSI-Pro is to be sent to the cash register and the cash 
register receives the data on its RXD.  
 

• 

Shielding 

 

The metal shield of a DB9 connector is normally connected to 
the shield of the cable to eliminate RFI and EMI interference in 
the RS-232 signal. In the Opto232 the metal shield of each 
DB9 connector is not connected to anything so a true isolation 
between input and output. Therefore the shield of any cable to 
the Opto232 must be connected to the shield of the sending or 
receiving device since no connection is made to or through the 
Opto232. 
 

• 

VSI-Pro Connection 

 

In most cases the Opto232 can plug in line with all the stan-
dard cash register cables from AVE. It also can plug directly to 
the DB9F connector on the rear of the VSI-Pro. A standard 
CR-802 cable which is a DB9M to DB9F 9 conductor exten-
sion cable can also work between the VSI-Pro and the Op-
to232 or between the Opto232 and the register. 

 

Page 3 

Summary of Contents for Opto 232

Page 1: ...Opto 232 Adapter Applications and Operation Manual...

Page 2: ...e at a higher voltage other than zero or ground When this high voltage ground is connected to the cash register ground all kinds of problems can arise and can damage either the CCTV system or the cash...

Page 3: ...ld of a DB9 connector is normally connected to the shield of the cable to eliminate RFI and EMI interference in the RS 232 signal In the Opto232 the metal shield of each DB9 connector is not connected...

Page 4: ...signal with the VSI Pro ground directly to the DVR before the Op to232 and isolate the ground from the DVR from the cash reg ister If you wish to isolate the ground of the VSI Pro from the DVR then y...

Page 5: ...onnected to power of the Opto232 OFF N C 9 N C DB9F from Cash Register Side 1 N C 2 RXD 3 TXD 4 DTR JP1 1 2 ON Connected to power the Opto232 1 2 OFF Not Connected to power the Opto232 JP2 3 4 ON Shor...

Page 6: ...Page 6 Opto 232 Adapter JP1 2 4 1 3 JP4 2 4 1 3 JP3 2 4 Hydra Regcom 2 1mm X 5 5mm DC Coax Jack...

Page 7: ...CR 802 or Plug Direct Multi Function Cable M Cash Register F Use Standard Emulate Tap Cable M F VSI Pro CR 802 or Plug Direct USB RS232 Adapter VSI Pro Opto 232 Opto 232 VSI Pro Opto 232 with DVR Net...

Page 8: ...232 Powered by PC VSI Pro to PC External Power PC PIN 7 8 PIN 4 6 Powered PIN 7 8 PIN 4 6 Powered VSI Pro VSI Pro M F Opto 232 Gender Changer Gender Changer CR 802 or Plug Direct CR 802 or Plug Direc...

Page 9: ...Cable VSI Pro with Vnetworker Opto 232 CR 802 or Plug Direct CR 802 M F Vnetworker VSI Pro Opto 232 Use Standard Emulate Tap Cable VSI Pro Opto 232 Cash Register Emulate Protocol VSI Pro CR 802 or Pl...

Page 10: ...______________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _________________________...

Page 11: ...______________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _________________...

Page 12: ...om NORTH AMERICA AVE USA 2000 West Governors Circle Suite E Houston Texas 77092 Tel 281 443 2300 Fax 281 443 8915 Email aveus ave us com Website www americanvideoequipment com UK and Western Europe AV...

Reviews: