SPECIFICATIONS

Electrical Characteristics

Operating Voltage.......................................................................9 - 12VDC
Supply Current.................................................................< 200mA @ 12VDC
Data Ports........................................1 x RS-232 (DB-9), 2 x RS-485 (RJ45)

Physical Characteristics

Size................................................130 x 125 x 32 mm / 5.1 x 4.9 x 1.3 in
Weight..................................................................................600 g / 1.3 lbs
Case......................................................................................Beige Metal

RS-232 Parameters

Baud Rate........................................................................................9600
Data Bits...............................................................................................8
Parity..............................................................................................None
Stop Bits...............................................................................................1

Network Parameters

Standard.......................................................................................RS-485
Max Line Length.............................................................................4000 ft
Cable Type................................................................120 Ohm Terminated

Summary of Contents for HYDRA RS-485

Page 1: ...1 HYDRA January 2007 RS 485 Network System Master Operation Manual...

Page 2: ...E PARTS ARE INSIDE REFER SERVICING TO QUALIFIED PERSONNEL CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN WARNING THIS EQUIPMENT GENERATES USES AND CAN RADIATE RADIO FREQUENCYENERGY AND IF NOT INSTALLEDA...

Page 3: ...tics Operating Voltage 9 12VDC Supply Current 200mA 12VDC Data Ports 1 x RS 232 DB 9 2 x RS 485 RJ45 Physical Characteristics Size 130 x 125 x 32 mm 5 1 x 4 9 x 1 3 in Weight 600 g 1 3 lbs Case Beige...

Page 4: ...er slave units for the purpose of transaction logging The Hydra receives RS 485 data from the Regcom Networker Vnetworker networks and converts this to an RS 232 format that DVRs or the VSI Pro can re...

Page 5: ...Switch No 8 is the terminal switch When set to ON the device is terminated When set to OFF it will be un terminated Figure 2 Regcom Rear Panel RJ45 PIN 4 PIN 5 RJ45 PIN 4 PIN 5 Table 3 RS 485 Network...

Page 6: ...has completed successfully and that the unit is functioning correctly Status light A will flash whenever data is received at the RS485 input Cable Connections Hydra PC DVR VSI Pro DB9M DB9F DB9M GND...

Page 7: ...elessness improper storage hostile operating conditions or unauthorized service installation or repairs without proper training from the Seller 3 damages caused by fire flood lightning collision acts...

Page 8: ...i http www avethailand com English NORTH AMERICA AVE Multiview USA 2000 West Governors Circle Suite E Houston Texas 77092 Tel 1 281 443 2300 Fax 1 281 443 8915 Email sales aveusa com http www american...

Reviews: