- 29 -
Reference standards
Conforms to standard CEI 79.2 1st level, to the general emission standard CEI-EN50081-1 and immu-
nity standard CEI-EN50130-4 for electromagnetic compatibility and to standard CEI-EN60950 for
electrical safety.
note:
this conformity is also valid for the AF45342 remote activation point and the AF45339 electronic
key.
Power supply unit
The power supply unit inside the control panel has two outputs:
•
Output for the system power supply and internal battery recharge, 13.8 Vdc (terminal 1).
•
Output for recharging the self-powered siren battery 14.5 Vdc (terminal 19)
The power supply unit output is electronically protected against overloads; The total current at the two
outputs must not exceed the maximum value of 280mA. Three self-resetting electronic protections
against overloads and short-circuits are also provided for and seated on the board:
•
PTC - 1A - to protect against battery inversion
•
PTC - 1A - to protect the siren circuit
•
PTC - 1A – to protect the system line (detectors and remote activation points)
To make the total rating calculation easier, refer to the following table:
note: to assure the 24h-endurance of the system in the case of mains failure, it is neces-
sary not to exceed the maximum rating value equal to 50 ma.
Ref. No.
Description Consumption
Quantity Total
(ma)
consumption (ma)
AF53907
4-zone control unit
15
1
15 +
AF45342
Activation/zoning
7
.........
......+
AF45...60
Flush-mounted PIR detector
0,1
.........
......+
AF45...62
Flush-mounted PIR detector
7
.........
......+
AF960
Wall-mounted PIR detector
0,1
.........
......+
AF962
Wall-mounted DT detector
7
.........
......+
=
Max value = 50ma
➪