background image

Manual No.

Issue

Change Note No.

Date

B

07/044

02-07

B2

07/103

03-07

07900-00822

www.avdel-global.com

©

 A

vd

e

U

K

 L

im

it

e

d

  

2

0

0

7

AUSTRALIA
Acument Australia Pty Ltd.

891 Wellington Road
Rowville, Victoria 3178
Tel: +61 3 9765 6400
Fax: +61 3 9765 6445
Email: [email protected]

CANADA
Avdel Canada, a Division of Acument
Canada Limited.

87 Disco Road
Rexdale
Ontario M9W 1M3
Tel: +1 416 679 0622
Fax: +1 416 679 0678
Email: [email protected]

CHINA
Acument China Ltd.

RM 1708, 17/F., Nanyang Plaza,
57 Hung To Rd., Kwun Tong
Hong Kong
Tel: +852 2950 0631
Fax: +852 2950 0022
Email: [email protected]

FRANCE
Avdel France S.A.S.

33 bis, rue des Ardennes
BP4 
75921 Paris Cedex 19
Tel: +33 (0) 1 4040 8000
Fax: +33 (0) 1 4208 2450
Email: [email protected]

GERMANY
Avdel Deutschland GmbH

Klusriede 24
30851 Langenhagen
Tel: +49 (0) 511 7288 0
Fax: +49 (0) 511 7288 133
Email: [email protected]

ITALY
Avdel Italia S.r.l.

Viale Lombardia 51/53
20047 Brugherio (MI)
Tel: +39 039 289911
Fax: +39 039 2873079
Email: [email protected]

JAPAN
Acument Japan Kabushiki Kaisha

Center Minami SKY,
3-1 Chigasaki-Chuo, Tsuzuki-ku,
Yokohama-city, Kanagawa Prefecture
Japan 224-0032
Tel: +81 45 947 1200
Fax: +81 45 947 1205
Email: [email protected]

SINGAPORE
Acument Asia Pacific (Pte) Ltd.

#05-03/06 Techlink
31 Kaki Bukit Road 3
Singapore, 417818
Tel: +65 6840 7431
Fax: +65 6840 7409
Email: [email protected]

SOUTH KOREA
Acument Korea Ltd.

212-4, Suyang-Ri,
Silchon-Eup, Kwangju-City,
Kyunggi-Do, Korea, 464-874
Tel: +82 31 798 6340
Fax: +82 31 798 6342
Email: [email protected]

SPAIN
Avdel Spain S.A.

C/ Puerto de la Morcuera, 14
Poligono Industrial Prado Overa
Ctra. de Toledo, km 7,8
28919 Leganés (Madrid)
Tel: +34 (0) 91 3416767
Fax: +34 (0) 91 3416740
Email: [email protected]

UNITED KINGDOM
Avdel UK Limited

Pacific House
2 Swiftfields
Watchmead Industrial Estate
Welwyn Garden City
Hertfordshire
AL7 1LY
Tel: +44 (0) 1707 292000
Fax: +44 (0) 1707 292199
Email: [email protected]

USA
Avdel USA LLC

614 NC Highway 200 South
Stanfield,
North Carolina 28163
Tel: +1 704 888-7100
Fax: +1 704 888-0258
Email: [email protected]

Summary of Contents for HP21

Page 1: ...HydraPac Hydraulic Power Unit HP21 HP41 HP51 Instruction Manual...

Page 2: ......

Page 3: ...y seller The only warranties made with respect to such unit or part s thereof are those made by the manufacturer thereof and seller agrees to cooperate with buyer in enforcing such warranties when suc...

Page 4: ...f the trailing cable with any object on the floor 10 The HydraPac should be kept clean for safe and easy operation 11 When moving the HydraPac from place to place only pull on the handle not on the ho...

Page 5: ...Working Pressure Pull 55 2 mPa 8000 psi Return 20 7 ma 3000 psi Delivery Volumes 2 6 l min 3 3 l min 3 3 l min Hydraulic Fluid ISO VG 46 OR EQUIVALENT Pump 4 Cylinder radial Control 24V dc solenoid c...

Page 6: ...tiated If the Tool Trigger switch in not depressed within a preset period normally set at 10 seconds for T10 Tools 15 seconds for T30 Tools and 25 seconds forT51 Tools the HydraPac will enter its Slee...

Page 7: ...e should be taken not to lose the square section rubber cushion between the Nut and the Coil and the O Ring behind the Coil Assembly of the coil is simply the reverse to the stripping procedure above...

Page 8: ...e symbol T is located on top Tighten the eight Nyloc Nuts 36 to 30 Nm in an opposing sequence using a 17 mm socket and torque wrench Assembling the Combination Valve Replace the two Plungers 109 in th...

Page 9: ...close the Valve A reading the pressure on the gauge take note of the pressure when the release valve opens Adjust the screw on the left hand side Spring Dome the lower of the two domes to obtain the s...

Page 10: ...2 ENCLOSURE ASSEMBLY 32 GLAND C109 18 29 28 27 26 25 24 23 22 16 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 TO ENCLOSURE 15 14 21 20 13 TO S...

Page 11: ...R 1 11 CO95 SURGE ARRESTOR 1 12 CO30 ISOLATOR 1 13 C081 TRANSFORMER 220V 1 14 CO35 ECCENTRIC SHAFT BEARING 1 15 CO34 STUD 8 16 CO22 MOTOR 1 17 CO89 MOUNTING PLATE 1 18 C104 GLAND 1 19 CO93 TRAILING CA...

Page 12: ...12 ENCLOSURE ASSEMBLY 32 GLAND C109 18 29 28 27 26 25 24 23 22 16 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 TO ENCLOSURE 15 14 21 20 13 TO...

Page 13: ...STOR 1 11B CO96 SURGE ARRESTOR 1 12 CO30 ISOLATOR 1 13 C082 TRANSFORMER 1 14 CO35 ECCENTRIC SHAFT BEARING 1 15 CO34 STUD 8 16 CO23 MOTOR 1 17 CO89 MOUNTING PLATE 1 18 C104 GLAND 1 19 CO94 TRAILING CAB...

Page 14: ...12 ENCLOSURE ASSEMBLY 32 GLAND C109 18 29 28 27 26 25 24 23 22 16 19 17 9 SCREW 4 OFF 2A B 1 FRAME COMPLETE CHASSIS OIL TANK LID AND GASKET OUTER FRAME AND HANDLE 35 33 TO ENCLOSURE 15 14 21 20 13 TO...

Page 15: ...TOR 1 12 CO30 ISOLATOR 1 13 C150 TRANSFORMER 1 14 CO35 ECCENTRIC SHAFT BEARING 1 15 CO34 STUD 8 16 CO24 MOTOR 1 17 CO89 MOUNTING PLATE 1 18 C104 GLAND 1 19 CO94 TRAILING CABLE 1 20 CO52 THERMAL OVERLO...

Page 16: ...ST 101 C116 DIRECTIONAL VALVE 1 102 CS26 SOCKET HEAD CAP SCREW 4 103 CS12 SOCKET HEAD CAP SCREW 8 104 CS34 SOCKET HEAD CAP SCREW 2 105 XN014 HEXAN NUT 2 106 CO41 SPRING DOME 2 107 CO42 BEARING PAD 2 1...

Page 17: ...ctor 21 Transformer 13 and the Bridge Rectifier 27 can now be removed and replaced using a flat screwdriver and a 7 mm spanner If it becomes necessary to effect major maintenance on the motor the Encl...

Page 18: ...L 3 L 3 T 3 I C F TF T BR R 1 220 230 v 50 hz 1 14 3 4 14 5 8 6 3 1 13 I 7 T O L LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M1 SINGLE PHASE MOTOR T F TRANSFORMER T TRIGGER SWITCH R...

Page 19: ...T 2 L 3 L 3 T 3 I C T O L F TF T BR R 1 400 415v or 525v 50 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 2 LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M3 THREE PHASE MOTOR T...

Page 20: ...2 L 2 T 2 L 3 L 3 T 3 I C T O L F TF T BR R 1 525v 50 hz 3 14 3 4 14 5 8 6 3 1 13 I L 1 L 1 L 2 E E S 1 S 1 LEGEND I LOCK OUT ISOLATOR C CONTACTOR T O L THERMAL OVERLOAD M3 THREE PHASE MOTOR T F TRAN...

Page 21: ...ter Launder contaminated clothing ORAL If swallowed and person is conscious give water or milk Do not induce vomiting unless on advice of medical personnel Take person to nearest medical centre EYES F...

Page 22: ...are faulty cycle Electrical Connections to the Solenoid Valve are sound Solenoid is faulty Direction Valve Spool is jammed Bridge Rectifier has burnt out The manifold Flange has come loose causing o...

Page 23: ...rial Estate Welwyn Garden City Herts AL7 1LY declare under our sole responsibility that the product Model HP21 HP41 HP51 Serial No to which this declaration relates is in conformity with the following...

Page 24: ...20047 Brugherio MI Tel 39 039 289911 Fax 39 039 2873079 Email vendite acument com JAPAN Acument Japan Kabushiki Kaisha Center Minami SKY 3 1 Chigasaki Chuo Tsuzuki ku Yokohama city Kanagawa Prefectur...

Reviews: