N o s e A s s e m b l i e s
I M P O R T A N T
Air supply must be disconnected when fitting or removing nose assemblies
•
Fit Locking Ring
8
onto the Chuck Collet Adaptor.
•
Lightly coat Jaws
4
with Moly Lithium grease.
•
Drop Jaws
4
into Chuck Collet
9
.
•
Insert one Spring Guide
10
into Chuck Collet
9
.
•
Locate Spring
7
onto the Spring Guide
10
already in place.
•
Drop the other Spring Guide
10
into Spring
7
.
•
Holding tool pointing down, screw the assembled Chuck Collet onto the Chuck Collet Adaptor and tighten with spanner.
•
Screw Anvil Adaptor
15
into the Head Assembly.
•
Place Anvil
12
over Chuck Collet
9
and lock into place with Anvil Nut
16
.
F i t t i n g I n s t r u c t i o n s M a x l o k
®
16
15
7
10
9
4
10
12
8
S e r v i c i n g I n s t r u c t i o n s
•
Remove nose assembly from tool using the reverse procedure to the fitting instructions above.
•
Clean parts. Worn or damaged parts should be replaced.
•
Check the Anvil
12
for wear and/or damage to the swaging bore.
•
Lightly coat Chuck Jaws
4
and Chuck Collet
9
internal bores with Molylithium grease.
•
Assemble as above instructions.