![Avdel 0753 MkII Instruction Manual Download Page 11](http://html1.mh-extra.com/html/avdel/0753-mkii/0753-mkii_instruction-manual_3028453011.webp)
11
P u t t i n g i n t o S e r v i c e
Loading the Tool
•
Connect the air supply to the tool.
•
Open tail jaws
9
which grip the mandrel, by switching off the tail jaw switch (items
26
and
30
).
•
Screw selected nose jaws onto barrel
25
of the tool.
•
Insert a mandrel into the tail end of the fasteners through the paper pod.
•
Slide the mandrel follower spring onto the mandrel ensuring correct orientation, as shown in the table on page 12.
•
Gripping the tail end of the mandrel, tear off the paper pod from around the fasteners.
•
Open the nose jaws either by rotating the outer ring on Cam operated jaws or by pushing outwards on the jaw ends, as illustrated
below left.
•
Insert the previously assembled mandrel, mandrel follower spring and fasteners into the nose jaws until the first fastener to be placed
is protruding from the nose jaw.
•
Close the nose jaws and adjust so that the first fastener protrudes by 1.5mm - 3mm (
1
/
16
” to
1
/
8
”), as shown in the illustration
below right.
•
Close the tail jaws to ensure the mandrel is gripped, by switching on the tail jaw switch (items
26
and
30
).
•
Push the fastener, protruding from the nose jaws, fully into the application holes ensuring that the tool is held square.
•
Operate the trigger without releasing - the mandrel head is pulled through the fastener, forming the fastener into the application.
•
Remove the tool.
•
Release the trigger. The next fastener will be automatically presented through the nose jaws, ready for placing.
Reloading the Tool
•
Open tail jaws
9
of tool.
•
Open the nose jaws and pull the empty mandrel and mandrel follower spring out of the tool.
•
Reload the tool by following the above instructions, starting at stage.
1.5mm - 3mm
(
1
/16
" -
1
/8
")
IMPORTANT
You must check that the cursor orientation and the nose equipment are correct before attempting to operate the tool.
Item numbers in
bold
refer to the general assembly and parts list for the 07530-02200 MkII type on pages 28-29. For the 07532-02200 MkII
type, the procedure is the same but the part numbers must be taken from the general assembly and parts list on pages 30-31.
O p e r a t i n g P ro c e d u r e
Summary of Contents for 0753 MkII
Page 2: ......
Page 38: ...38 Notes...