Safety
23
Electrical Safety
The power cable of the SCOPIA Elite 5200 Series MCU platform should only be
connected to a power outlet that has a protective earth contact. Do not use an
extension cord that does not have a protective conductor (ground).
Caution
For North American installations, select a 3-conductor (18 AWG) power
supply cord that is UL listed and CSA certified. The cord must be terminated in a
molded-on plug cap rated 125V/5A, with a minimum length of 1.5m (6 feet) and
no longer than 4.5m (approximately 14 feet).
Caution
This is a class I unit. In Denmark, use this unit with an AC cord suited
to Danish specifications. The cord should include an earthing conductor. Plug the
unit into a wall socket outlet which is connected to the protective earth contact. Do
not use socket outlets which are not connected to a protective earth contact!
Varoitus
Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan.
Advarsel
Apparatet må tilkoples jordet stikkontakt.
Varning
Apparaten skall anslutas till jordat uttag.
P
OWER
S
UPPLY
Caution
Risk of electric shock and energy hazard. This unit might have more
than one power supply connection. All connections must be removed to
de-energize the unit.
Caution
To avoid problems or damage to the chassis, do not mix DC-input power
supplies with AC-input power supplies in individual chassis.
The line modules and redundant power supplies are designed to be removed and
replaced while the system is operating, without presenting an electrical hazard or
risking damage to the system.