To ensure the ports are physically connected correctly, ask the switch 

 

a administrator to place calls to each individual INTUITY voice 

 

channel one at a time.  Use the “System Monitor” menu in INTUITY 

 

to monitor that the correct channel is dialed from the switch. 

7.2  TESTING THE INSTALLATION 

Refer to the AUDIX Administration manual for further details on 

 

testing the installation. 

Testing the installation when 

complete 

Create two mailboxes associated with two test extensions. Record a 

 

name and personal greeting for each mailbox. 

  

Using one test extension, call the other test extension. You should 

 

hear the appropriate greeting (see test scenarios below). 

 

 Leave a message. Verify that message waiting indication turns on. 

 

Test 

call 

coverage 

scenarios:      

 

Forward all calls - When a subscriber forward all calls to the 

 

Intuity number, calls placed to the subscriber should follow the 

 

correct Intuity prompt should be played for  that subscriber. 

 

Busy - Place a call to a busy extension.  This should follow the right 

 

coverage path and Intuity should play the NO ANSWER greeting. 

 

Call no answer from Intuity scenario is the same as above. 

Message waiting indicators - 

 

Listen to the message left for the mailboxes above, delete the 

 

message and verify message waiting is turned off. 

Summary of Contents for Definity G3 / ProLogix

Page 1: ...celed using DTMF commands over the same pathway With inband integration one pathway between the PBX and Intuity system transmits both call information and voice communications 2 0 AVAYA INTUITY ORDERI...

Page 2: ...ogramming the PBX to integrate They are as follows Configuring the PBX to integrate Enable Mode Code Integration Configure each analog voice port Configure the analog voice ports into a UCD group Crea...

Page 3: ...Configuring Hunt Group for the Intuity ports 5 3 HUNT GROUP ADMINISTRATION After all the analog lines to be connected to the Intuity ports are configured they need to be installed into a Hunt Group o...

Page 4: ...a Coverage Path will send busy and ring no answer calls to the Intuity to be answered Assign the Intuity ports Hunt Group as the coverage point for each subscriber Enter ADD COVERAGE PATH n n is an av...

Page 5: ...udible Message Waiting Indicator is supported in conjunction with lamps only if this optional feature is enabled on the PBX 6 0 CONFIGURING THE INTUITY o The following define the steps required on the...

Page 6: ...ice Name AUDIX Assignment of Channel to Groups Select Voice System Administration menu Select Voice Equipment menu Select ACTIONS button this will bring up the Actions menu Select Assign Change option...

Page 7: ...ber extension length Administer extension ranges in the table as follows 1 Leave Switch Prefix field blank 2 Enter the valid extension ranges in Switch Start Ext and Switch End Ext fields 3 Leave INTU...

Page 8: ...Service and Night Service Mailboxes will have to be administered and an appropriate greeting must be recorded 7 0 HARDWARE INSTALLATION o Each IVC6 card supports six analog tip ring connections The vo...

Page 9: ...sting the installation when complete o Create two mailboxes associated with two test extensions Record a name and personal greeting for each mailbox o Using one test extension call the other test exte...

Page 10: ...l access number and the mailbox number followed by the sign the Intuity will prompt for the password Do you hear Please enter your password o Automated Attendant Call the automated attendant mailboxes...

Page 11: ...sy no answer internal and external are not supported All calls are re directed to the Intuity Audix are treated as no answer external calls 8 8 Check the availability of TN746B or TN742 analog ports i...

Page 12: ...SM and TM are registered trademarks servicemarks or trademarks respectively All other trademarks are properties of their respective owners The above information is based on knowledge available at the...

Reviews: