Installation and Configuration
Avaya DECT R4 - Installation and Maintenance Guide
06/2009
205
Installation and Configuration
Rackmount Charger Installation
General
!
Important:
Important:
The unit shall be installed by authorized personnel only.
●
The units shall be placed in a dry environment with a temperature range from
+5° C up to + 40° C (41° F to 104° F).
●
The units shall be mounted on a vertical wall.
●
Avoid mounting the Rackmount Charger in a sunlit place. This can affect the charging
capacity.
●
Avoid mounting the Rackmount Charger where radio/network coverage is not sufficient.
This can reduce the messaging capacity.
●
The unit shall be mounted on concrete or plaster walls only.
●
If the Rackmount Charger is connected to a power supply via an AC wall plug, serial power
supply connection is not allowed.
●
If the Rackmount Charger is connected to a power supply via an AC wall plug, the
socket-outlet shall be situated near the equipment and shall be easily accessible.
●
If the Rackmount Charger is connected to a power supply via a fixed connection, a readily
accessible disconnect device shall be incorporated in the building installation wiring.
Delivery includes:
●
Rackmount Charger
●
Power supply cord including IEC C14 connector (male)
●
Inlet accessory kit including cable support holders and screws
Note:
Note:
An extension cord IEC C14 AC connector (female IEC60320-C13) to wall socket
(IEC60320-C14) has to be ordered separately. It shall be connected between the
pre-installed IEC C14 AC connector (male) and the wall socket.
Required Tools etc.
●
Screwdrivers