Wait until the new DAP appears in the DAP list of the DAP manager.
11. Click
Edit
.
12. In the
RPN
field of the new DAP, enter the
RPN value
you recorded after you
removed the old DAP in step 4.
13. Click
OK
.
After the new DAP restarts, verify that it has the RPN of the DAP you removed.
System synchronization analysis
Use the information in this section to manually synchronize the DECT system, and eliminate
possible synchronization problems.
An analysis tool called Synchronization Analyzer is available in the DAP Configurator. You can
use this tool to generate a graphical overview of the synchronization structure in the system
and to calculate the best candidate for the synchronization master. You can also use it to detect
potential problems in the synchronization structure.
Synchronization Analyzer provides the following information displays:
• a hierarchical view of the DAP Synchronization using visibility files
• a three-dimensional localization of DAPs using location files
• a Traffic Bearer Control file analysis, which you can use to trace which DAPs a handset
used during a call
Synchronization Analyzer interface
This section describes the Synchronization Analyzer interface.
To access the Synchronization Analyzer, click Start > All programs > DAP controller > DAP
Applications > DAP Sync Analyzer.
Synchronization Analyzer main page
The following screen capture shows the main window, which is displayed when the Sync
Analyzer is started.
System synchronization analysis
SIP DECT Fundamentals
October 2012 153
Summary of Contents for CS 1000
Page 6: ...6 SIP DECT Fundamentals October 2012 ...
Page 146: ...System administration 146 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 174: ...System maintenance 174 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 204: ...Site survey example 204 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...