CTM; Reviewed:
SPOC 11/29/2007
Solution & Interoperability Test Lab Application Notes
©2006 Avaya Inc. All Rights Reserved.
40 of 51
AudioCodesMP118.doc
Step
Description
20.
Hunt Group Settings
Select
Protocol Management
in the left pane and navigate to
Hunt Group Settings
in
the right pane.
Configure the parameters are described below.
For
Hunt Group ID
1
which contain the FXS (endpoint) ports, select the
Channel Select Mode
as
By Dest Phone Number
. Thus, each port in this hunt
group will only be selected if its destination phone number is dialed. Select the
Registration Mode
to be
Per Endpoint
.
For
Hunt Group ID
2
which contain the FXO (POTS) ports, select the
Channel Select Mode
as
Cyclic Ascending
. The ports in this hunt group are
treated as a pool, and each will be selected in cyclic ascending order. Select the
Registration Mode
to be
Per Gateway
. This allows the MP-118 to register
once for all the FXO ports using the gateway extension entered in Step 7. The
MP-118 requires that both the FXS and FXO ports be registered since
registration was enabled in Step 6. For the compliance test, it was chosen to
register once for all the FXO ports since it is not intended that the FXO ports be
accessed using the gateway extension.
Click
Submit
.