background image

Section 2: Technical Data

Revision 2

27

LAN C

ABLE

Part No:

CABETHNN03M0PP00

Sales Feature:

ARG-LAN3C

Supply:

Optional extra.

This cable is used when connecting Hub Ports 1 – 7 directly to a PC.

A

RJ45 Plug.

B

RJ45 Plug.

C

Cat 5 UTP cable – GREY.

D

3  metres.

Pin Connections

End A

Colour

Cable Notes

End B

1

White/Orange

1

2

Orange/White

2

3

White/Green

3

6

Green/White

6

4

Blue/White

4

5

Blue/White

5

7

Blue/White

7

8

Blue/White

8

D

A

B

C

Twisted Pair

Twisted Pair

Twisted Pair

Twisted Pair

Summary of Contents for ArgentBranch

Page 1: ...ArgentBranch Hardware Reference Manual Revision 2...

Page 2: ...s All rights reserved No part of this publication may be reproduced transcribed stored in an electronic retrieval system translated into any language or computer language or be transmitted in any form...

Page 3: ...0 Rear View 12 Port Connections 13 DTE Port 13 DC Power Input Connector 13 Connection to Primary Rate ISDN PRI 13 Audio Input Connector 14 Connection to an X 21 V 35 or V 24 V 28 Leased Line 14 Argent...

Page 4: ...8 V 24 V 28 WAN Cable 29 X 21 WAN Cable 30 V 35 WAN Cable 31 Port Safety Classification 33 Technical Specifications 35 Interfaces 35 Protocols 36 Section 3 Fitting Upgrade Instructions 1 Rack Mounting...

Page 5: ...tBranch This section contains y About ArgentBranch page 6 y Safety and Homologation Statements page 9 y Further Information and Product Updates page 10 y Product Variants page 11 y Port Labelling page...

Page 6: ...and allow you to enjoy the fruits of your consequent success ARGENTBRANCH MODULES The Alchemy ArgentBranch system consists of a series of modules that may be shelf or rack mounted as desired Modules i...

Page 7: ...ax lines y Answer Phone Voice Mail for unanswered calls y Call logging outgoing and incoming The main ArgentBranch Office Router features y Access Router Software y Integral 8 port Ethernet Hub 10 100...

Page 8: ...Approval Statements Safety Declarations Port Labelling and Pin Out Information Cable Specifications and Technical Specifications For configuration information and an overview of the advanced features...

Page 9: ...d as this will prevent calls being forwarded to unconnected extensions BRI Interface During the configuration ensure 000 emergency number is not barred by performing the following Short Code 000 Telep...

Page 10: ...on 2 FURTHER INFORMATION AND PRODUCT UPDATES Further information including Product and Reference Manual updates can be obtained from Avaya Inc Alchemy Dealers and Distributors or from Avaya Inc Alchem...

Page 11: ...us data port y 6 x Expansion ports for connecting to ArgentPhone modules y 8 x 10BaseT 100BaseT LAN ports y 1 x External Control port y 1 x Audio input port y 1 x Free ISDN Slot for 2nd PRI card or fo...

Page 12: ...roduct Expansion Port WAN Port Unit LAN Link LAN Ports Status LEDS Status Status OK LED 1 8 1 6 LED LED ISDN Port LAN LAN Daisy Chain Status LEDS Collision Activity switch for 1 8 LED LED LAN Port 8 A...

Page 13: ...port is used by manufacturing and is labelled DTE DC POWER INPUT CONNECTOR The ArgentBranch uses a Lump in Line PSU module to provide DC power The PSU module is plugged into a suitable mains power out...

Page 14: ...ction and can support an X 21 V 35 or V 24 V 28 interface The selection of the required interface is automatically determined from the pin out of the appropriate Alchemy Series cable plugged into the...

Page 15: ...d it can be obtained by ordering Sales Feature ARG VIC part number CABTDMSN01M0PP00 CONNECTION TO A LAN Connection to the LAN from the ArgentBranch may be made via one of the eight 10BaseT 100BaseT po...

Page 16: ...rt s electrical specifications can be found in Technical Specifications page 34 Details of the port pin out can be found in Port Pinouts page 17 CONNECTION TO BASIC RATE ISDN BRI The ArgentBranch 0808...

Page 17: ...Section 2 Technical Data This section contains y Port Pinouts page 18 y Cables page 23 y Port Safety Classification page 33 y Technical Specifications page 35...

Page 18: ...Pin No Description Signal Direction 2 Transmit Data TxD 3 Receive Data RxD 4 Request to Send RTS 5 Clear to Send CTS 6 Data Set Ready DSR 7 Signal Ground 8 Data Carrier Detect DCD 20 Data Terminal Rea...

Page 19: ...Receive data Rx A 2 Receive data Rx B 4 Transmit data Tx B 5 Transmit data Tx A LAN PORT 10BASET 100BASET RJ45 SOCKET The information below refers to LAN ports 1 7 Port 8 is switchable Pin 1 Pin 8 Pin...

Page 20: ...Ind B 3 V11 Clk A 22 V11 Clk B 4 V11 Tx A 23 V11 Tx B 5 V11 Ctl B 24 V11 Ctl A 6 V11 Gnd 25 WAN ID 0 7 WAN ID 1 26 V24 Tx 8 V24 DTR 27 V24 RTS 9 V24 Rx 28 V24 RxClk 10 V24 TxClk 29 V24 RI 11 V24 DCD...

Page 21: ...escription Signal Direction Common Common Left Audio In Left Channel Right Audio In Right Channel EXPANSION PORT RJ45 SOCKET Pin 1 Pin 8 Pin No Description Signal Direction 1 Receive Data Rx B 2 Recei...

Page 22: ...nnected Control Circuit Information Control Circuit 1 Pin 2 and Pin 3 ensure that Pin 2 is at a positive voltage with respect to Pin 3 Control Circuit 2 Pin 1 and Pin 3 ensure that Pin 1 is at a posit...

Page 23: ...RJ45 Plug C Cat 5 UTP cable RED D 3 metres Important This cable must not exceed 3m in length Pin Connections End A BRI PRI Colour Cable Notes End B 4 Rx A Tx A Blue White 4 5 Rx B Tx B White Blue 5 3...

Page 24: ...03mm 24 a w g tinned copper stranded wire nominal capacitance of 95pF m resistance of 92 km screened with tinned copper braid maximum working voltage of 440V r m s and a Maximum current per core of 1A...

Page 25: ...HSIC Supply Optional extra This cable is used when connecting the ArgentWAN 3 to the ArgentBranch A RJ45 Plug B RJ45 Plug C Cat 5 UTP cable GREEN D 1 metre Pin Connections End A Colour Cable Notes En...

Page 26: ...ARG EX10C Supply Optional extra This cable is used when connecting Hub Ports 1 7 directly to another Hub A RJ45 Plug B RJ45 Plug C Cat 5 UTP cable BLACK D 3 metres Pin Connections End A Colour Cable...

Page 27: ...when connecting Hub Ports 1 7 directly to a PC A RJ45 Plug B RJ45 Plug C Cat 5 UTP cable GREY D 3 metres Pin Connections End A Colour Cable Notes End B 1 White Orange 1 2 Orange White 2 3 White Green...

Page 28: ...to the STP Cable Drain Wire A Shielded RJ45 Plug B Shielded RJ45 Plug C STP Shielded Twisted Pair cable BLUE D 1 metre Pin Connections End A Name Colour Cable Notes End B 1 Rx A White Orange 1 2 Rx B...

Page 29: ...with tinned copper braid maximum working voltage of 440V r m s and a Maximum current per core of 1A r m s E 3 metres Important This cable must not exceed 3m in length Pin Connections End A Name End B...

Page 30: ...ce of 98pF m impedance of 77 at 1MHz screened with aluminised tape and a tinned copper wire drain E 3 metres Important This cable must not exceed 3m in length Pin Connections End A Name Cable Notes En...

Page 31: ...ance of 98pF m impedance of 80 10 at 1MHz screened with aluminised tape and a tinned copper wire drain E 3 metres Important This cable must not exceed 3m in length Pin Connections End A Name Cable Not...

Page 32: ...eceive Clock A V 18 Receive Clock B X 33 External Clock A U 15 External Clock B W 34 Ground B Connect pins 7 and 25 to pin 6 at End A only Pin 19 at end A is connected to the Screened Cable Drain Wire...

Page 33: ...connection SELV WAN port WAN connection NET TNV Operating within the limits of SELV LAN ports 10BaseT 100BaseT SELV attachment to LAN Expansion ports Expansion Module connector SELV Audio port Connec...

Page 34: ...ows Port Name Port Description Port Classification BRI ports BRI ISDN connection TNV Operating NET within the limits of SELV Interconnection circuits shall be selected to provide continued conformance...

Page 35: ...N 1 x 37 way D Type female socket X 21 interface to 2048k bps V 35 interface to 2048k bps and V 24 Interface to 19k2 bps Audio 1 x 3 5mm Stereo Jack socket Input impedance 10k channel Operational inpu...

Page 36: ...ndshake Authentication Protocol CCP RFC 1962 Compression Control Protocol STAC RFC 1974 Stac LZS Compression Protocol MPPC RFC 2118 Microsoft Point to Point Compression Protocol BACP RFC 2125 Bandwidt...

Page 37: ...Upgrade Instructions This section contains y Rack Mounting Assembly Instructions page 2 y BRI PRI ISDN Module Upgrade Instructions page 3 y Modem Module Upgrade Instructions page 4 y Voice Compressio...

Page 38: ...Index 2 Revision 2 RACK MOUNTING ASSEMBLY INSTRUCTIONS...

Page 39: ...Index Revision 2 3 BRI PRI ISDN MODULE UPGRADE INSTRUCTIONS...

Page 40: ...Index 4 Revision 2 MODEM MODULE UPGRADE INSTRUCTIONS...

Page 41: ...Index Revision 2 5 VOICE COMPRESSION MODULE UPGRADE INSTRUCTIONS...

Page 42: ...Index 6 Revision 2...

Page 43: ...port 11 C cable sales features 14 call logging 7 caller display 6 7 communications protocols 7 conferencing facility 7 connection to a lan 15 connection to basic rate isdn 16 connection to primary rat...

Page 44: ...16 connection to primary rate isdn 13 dc power input connector 13 external control connector 16 port labelling 12 port pinouts dte port 18 23 lan port 10baset 100baset 19 port safety classification 3...

Reviews: