background image

13

Sources of Information

For information about an 1151D1 or 1151D2 power supply or instructions 
on how to install it, refer to this instruction booklet packed with the 
product. Additional installation information may often be found in the user 
or installation manual of the terminal or adjunct equipment used with the 
power supply. As the 1151D1 and 1151D2 are fourth generation power 
supplies, the original product manuals may describe use with the prior 
generation 1151A1/A2, 1151B1/B2 or 115C1/C2 models. Please note, 
the models 1151D1 and 1151D2 are not direct replacements for these 
legacy Avaya and Lucent models. The 1151D1 and 1151D2 should only 
be used in Separated Extra Low Voltage (SELV) rated IP-Telephone 
installations.  The 1151C1 and 1151C2 should be used for all 
non-IP-Telephone applications.

Power Supply Description

The 1151D1 power supply is a “desktop”, single output 48 volt dc, 20 watt 
power supply. The power supply can operate over a wide range of AC 
input voltage and frequency: 90 - 264 VAC, 47-63 Hz.
The 1151D2 power supply is a “desktop “, single output 48 volt dc, 20 
watt power supply 

with battery holdover

. The power supply can operate 

over a wide range of AC input voltage and frequency: 90 - 264 VAC, 47   
63 Hz. When AC power fails the battery (if fully charged) should provide 
approximately 15 minutes of holdover at full load (20 watts) or about 8 
hours at light load (2 watts). As many factors may impact battery 
performance (such as level of charge, age of the battery, temperature, 
etc.), actual performance will vary.

The 1151D1/D2 Power Supplies

The 1151D1/D2 Power Supplies can be used to supply local power to the 
following Lucent or Avaya products:

IP-Telephones, Models 4602, 4602SW, 4606, 4610SW, 4612, 
4620, 4620SW, 4621SW, 4622SW, 4624, 4625SW, 4630SW, 
5602, 5610, 5620SW, 9610, 9620, 9630, 9630G, 9640, 
9640G, and 9650, working with Avaya Communication 
Manager. The included Cat5 Cable may be used with all 
Avaya IP telephones, except the 9630G and 9640G. The 
9630G and 9640G telephones require a special power cord 
that is available for purchase from Avaya using comcode: 
700409857.

Note:

 Failure to use and install as directed could result in injury. No other 

use of the 1151D1/D2 Power supplies is recommended or warranted. At 
the time of publication, every effort has been made to insure accuracy of 
this manual. However, it is possible that 1) some omissions have 
occurred, or 2) new products have since been introduced that use the 
1151D1 or 1151D2 power supply. If you are unsure concerning the 
suitability of models 1151D1 or 1151D2 for a particular application, check 
your product documentation or contact your local Avaya representative 
for assistance.

!

CAUTION:

The 1151D1 and 1151D2 Power Supplies can 

only

 be used with 

telecommunications equipment, indoors, in a controlled environment.

Operation

The maximum loop range between the telephone and the power supply 
is 14 feet.
The 1151D1/D2 power supply is intended to replace the 1151C1/C2 for 
IP-Telephone applications only.
The 1151D1 power unit has a green LED that shows the unit has power 
on the PHONE jack, pins 7 & 8 when AC power is applied.
The 1151D2 power unit has two LED's: a green LED that shows the unit 
has power on the PHONE jack, pins 7 & 8 when AC power is applied or 
running on battery and a YELLOW LED that shows the unit is charging 
the battery when illuminated. When blinking, the GREEN LED indicates 
that the unit is running on battery power.
The 1151D2 incorporates an integrated feature that allows one to easily 
disable the output when the supply is disconnected from AC mains 
power. This allows storage of the power supply without rapid discharging 
of the internal sealed Lead-acid battery due to continued operation of the 
internal battery-voltage to output-voltage converter (henceforth referred 
to as the “boost converter”). After disconnecting the 1151D2 power 
supply from the AC mains following 1) normal use, or 2) periodic 
recharge maintenance of the internal battery, the user should do the 
following:

Locate the disable-switch access hole on the base of the 
1151D2 power supply. Insert a fine non-metallic object (such 
as a wooden or plastic toothpick) into the access hole and 
depress the recessed momentary contact switch. This 
operation disables the internal boost converter. Once the 
boost converter is disabled, all status LEDs will turn off (this 
may take a few seconds as the stored charge in the output 
filter capacitors is discharged). This operation should only be 
done when the power supply is to be stored or is to go 
through a period of non-use.

Note:

 One should 

not

 press the disable button when the supply is in 

active operation during a power failure. Once the boost converter disable 
button is pressed, the supply will no longer function until AC mains power 
is restored. When AC mains power is restored to the power supply, 
normal operation will resume.

Maintenance

The Avaya models 1151D1/D2 power supplies contain no user 
serviceable parts. To reduce the risk of electric shock, do not 
disassemble the product.
To clean the 1151D1/D2 power supply, first unplug the AC power cord 
from the wall receptacle (or other AC source) and disconnect all cords 
from the LAN/PBX and Phone RJ45 jacks. Do not use liquid cleaners or 
aerosol cleaners. Use a damp cloth for cleaning.
Like all batteries, the internal Lead-acid battery of the 1151D2 power 
supply will self-discharge over a period of inactivity and must be 
periodically recharged to avoid damage. This is not a concern during 
normal supply operation, as the power supply will automatically recharge 
as needed. However, when stored and disconnected from the AC mains 
for an extended period of time, the battery should be recharged every six 
months to prolong battery life and avoid damage resulting from deep 
discharge. This may be done by simply connecting the power supply to a 
source of AC power and allowing the battery to charge for at least twelve 
hours. When battery charging is complete, if the power supply is to be 
placed back into storage or disconnected again from the AC mains, one 
should immediately disable the battery boost converter as outlined in the 
“Operation” section above.

Contents of the 1151D1 and 1151D2 Boxes 

*If a longer network cable is desired, a 4.26m (14 ft) Cat5 patch cable is 
available for purchase from Avaya using comcode: 700204050
*If using the 1151D1/D2 with the 9630G or 9640G a special power cord is 
required.  It is available for purchase from Avaya using comcode: 
700409857.

Connecting the Power Supply

The power output is provided through a modular jack on the power 
supply. These jacks are labeled as follows:

The supply output is essentially isolated from earth ground and 
depending on the particular application, either output pin may be used to 
establish a reference potential. However, it is common in 
telecommunications applications to think of the supply output as nominal 
-48Vdc (pin 7) relative to a 0Vdc reference on pin 8.
The output jack, labeled “PHONE” is an 8-pin female non-keyed RJ45 
jack that can accept Cat5 (LAN) modular plug cables.
The input jack, labeled “LAN/PBX” is an 8-pin female non-keyed RJ45 
jack that can also accept Cat5 (LAN) cables. A Cat5 cable fitted with 
RJ45 modular plugs is provided with the supply. 

1151D1

 

Quantity

Comcode

1

1151D1 Power Supply

700434897

1

1.9m (6.23 ft) Cat5 Network Cable*

1

Clamp-on Ferrite

1

Installation & Safety Instructions

1151D2

 

Quantity

Comcode

1

1151D2 Power Supply

700434905

1

1.9m (6.23 ft) Cat5 Network Cable*

1

Clamp-on Ferrite

1

Installation & Safety Instructions

PHONE LAN/PBX 

Summary of Contents for 1151D1

Page 1: ...pe of AC power indicated on the product label If you are unsure of the type of AC power being provided contact a qualified service person Do not allow anything to rest on the power cord Do not locate...

Page 2: ...auch in gewissem Umfang IHRE Aufgabe Lesen Sie deshalb sorgf ltig die Hinweise auf dieser Seite Die an dieser Stelle gemachten Vorschl ge gew hrleisten den st rungsfreien Einsatz dieses Produkts Legen...

Page 3: ...www avaya com support CONSERVE ESTAS INSTRUCCIONES VIGTIGE SIKKERHEDSINSTRUKTIONER FOR BRUGEREN Der er blevet taget n je hensyn til kvalitetsstandarder under produktionen af Deres nye str mforsynings...

Page 4: ...e aandacht besteed aan de kwaliteitsnormen Veiligheid is een zeer belangrijke factor in het ontwerp van elke product van Avaya Maar veiligheid is ook UW verantwoordelijkheid Lees de onderstaande handi...

Page 5: ...ETSINSTRUKTIONER F R ANV NDAREN Tillverkningen av ditt str mf rs rjningsaggregat har skett med st rsta m jliga h nsyn till kvalitetsnormer S kerhet r en viktig faktor n r alla Avayas produkter utforma...

Page 6: ...entretien du personnel qualifi lorsque ces conditions sont pr sentes Le cordon de la prise d alimentation est endommag ou effiloch Un liquide a t renvers sur le produit Le dispositif a t expos une hum...

Page 7: ...obre o cabo de alimenta o N o coloque este produto num local onde o cabo fique sujeito a maus tratos como por exemplo pessoas a caminharem sobre o mesmo Assegure se de que o produto disp e de ventila...

Page 8: ...emi lub zosta a uszkodzona obudowa Je li stwierdzono nieprawid owe funkcjonowanie urz dzenia Deklaracja zgodno ci Aby pobra Declaration of Conformity Deklaracj zgodno ci DoC dla tego urz dzenia nale y...

Page 9: ...nos tan csokat Ezek a javaslatok lehet v teszik hogy a k sz l k minden el ny t kihaszn lhassa Az tmutat t rizze meg k s bb m g sz ks g lehet r Haszn lat A t pegys g haszn latakor a k vetkez biztons gi...

Page 10: ...l tipo de energ a CA indicado en la etiqueta del producto Si no est seguro del tipo de energ a CA de que dispone p ngase en contacto con un t cnico de servicio especializado No deje que nada se apoye...

Page 11: ...com support 1151D1 D2 TNV TNV AC AC AC AC Avaya 1151D2 AC AC Declaration of Conformity DoC http www avaya com support KO HE Avaya Avaya http www avaya com support TNV Avaya 1151D2 DoC support com avay...

Page 12: ...CISPR 24 and EN55024 including Electrostatic Discharge ESD IEC 61000 4 2 Radiated Immunity IEC 61000 4 3 Electrical Fast Transient IEC 61000 4 4 Surge Immunity IEC 61000 4 5 Conducted Immunity IEC 610...

Page 13: ...acid battery due to continued operation of the internal battery voltage to output voltage converter henceforth referred to as the boost converter After disconnecting the 1151D2 power supply from the...

Page 14: ...Telephone model 4630SW Figure 5 shows the local powering option arrangement for IP Telephone models 9610 9620 9630 9640 and 9650 Figure 6 shows the local powering option arrangement for IP Telephone...

Page 15: ...ferrite onto power supply end of Cat5 cable within 3 inches of connector as shown Less than 3 inches or 7 6 cm Ferrite Cat 5 Cord PHONE LAN PBX 1151D1 D2 DSS 4624 only optional Representative drawing...

Page 16: ...pply end of Cat5 cable within 3 inches of connector as shown Less than 3 inches or 7 6 cm Ferrite Cat 5 Cord 4610SW 5610SW Only 4610SW 5610SW Only These telephone models may also be powered over the n...

Page 17: ...ble supplied with IP telephone Note The 4622SW does not have a handset but instead can support a second headset Note These telephone models may also be powered over the network cabling from a central...

Page 18: ...errite onto power supply end of Cat5 cable within 3 inches of connector as shown Less than 3 inches or 7 6 cm Ferrite Note This powering option does not apply to the Avaya 4630 IP T elephone It is val...

Page 19: ...power supply end of Cat5 cable within 3 inches of connector as shown Less than 3 inches or 7 6 cm 1151D1 D2 PHONE LAN PBX Ferrite Note These telephone models may also be powered over the network cabli...

Page 20: ...d Note These telephone models may also be powered over the network cabling from a central location using an IEEE Std 802 3af compliant switch or midspan power supply The power cord for the 9630G 9640G...

Reviews: