Avaya 1151C1 Installation And Safety Instructions Download Page 13

13

Sources of Information

For information about an 1151C1 or 1151C2 power supply or instructions 
on how to install it, refer to this instruction booklet packed with the 
product. Additional installation information may often be found in the user 
or installation manual of the terminal or adjunct equipment used with the 
power supply. As the 1151C1 and 1151C2 are third generation power 
supplies, the original product manuals may describe use with the prior 
generation 1151A1/A2 or 1151B1/B2 models. The models 1151C1 and 
1151C2 are direct replacements for these legacy Avaya and Lucent 
models and may be substituted for them. (Please note that although the 
physical appearance of the power supplies have changed, the basic 
functionality has remained the same.)

Power Supply Description

The 1151C1 power supply is a “desktop”, single output 48 volt dc, 20 watt 
power supply. The power supply can operate over a wide range of AC 
input voltage and frequency: 90 - 264 VAC, 47-63 Hz.
The 1151C2 power supply is a “desktop “, single output 48 volt dc, 20 
watt power supply 

with battery holdover

. The power supply can operate 

over a wide range of AC input voltage and frequency: 90 - 264 VAC, 47   
63 Hz. When AC power fails the battery (if fully charged) should provide 
approximately 15 minutes of holdover at full load (20 watts) or about 8 
hours at light load (2 watts). As many factors may impact battery 
performance (such as level of charge, age of the battery, temperature, 
etc.), actual performance will vary.

The 1151C1/C2 Power Supplies

The 1151C1/C2 Power Supplies can be used to supply local power to the 
following Lucent or Avaya products:

IP-Telephones, Models 4602, 4602SW, 4606, 4610SW, 4612, 
4620, 4620SW, 4621SW, 4622SW, 4624, 4625SW, 4630SW, 
5602, 5610 and 5620SW working with Avaya Communication 
Manager. Use the included Cat5e cable, (Comcode 
700204050) with all IP telephones;

Adjunct equipment such as the EU24, EU24BL (when 
attached to a compatible IP or DCP telephone);

DCP compatible Expansion Modules such as the XM24, 1EM 
or 2EM, and other optional equipment including the 100A 
Analog Interface Module, 20A Stand with 200A Analog 
Adjunct Interface and/or 201A Recorder Interface Modules 
installed on DCP phones;

DCP Voice Terminal Series 64xx, 74xx and 84xx when 
needed for powering optional adjuncts, or where required as 
for the model 8411;

DCP 7444 and 8434 voice terminals which need auxiliary 
power for their vacuum fluorescent displays;

Adjunct equipment such as the S201A and CS201A 
speakerphones or a 500A Headset Adapter attached to any 
Analog, DCP, or ISDN-T voice terminal equipped with an 
Adjunct jack;

MLX-20L™, MLX-20LS™, MLX-28D™, MLX-28DS™ 
telephones connected to a Lucent or Avaya MERLIN 
LEGEND

®

 Communications System;

MLS-CA24 Call Assistant™ Intercom Autodialer (DSS) and 
the Remote Access Unit connected to a Lucent or Avaya 
PARTNER

®

 Communications System;

ISDN-T 65xx, 75xx, and 85xx series voice terminal 
connected to a Lucent or Avaya DEFINITY

®

 Communications 

System.

Note:

 Failure to use and install as directed could result in injury. No other 

use of the 1151C1/C2 Power supplies is recommended or warranted. At 
the time of publication, every effort has been made to insure accuracy of 
this manual. However, it is possible that 1) some omissions have 
occurred, or 2) new products have since been introduced that use the 
1151C1 or 1151C2 power supply. If you are unsure concerning the 
suitability of models 1151C1 or 1151C2 for a particular application, check 
your product documentation or contact your local Avaya representative 
for assistance.

!

CAUTION:

The 1151C1 and 1151C2 Power Supplies can 

only

 be used with 

telecommunications equipment, indoors, in a controlled environment.

Operation

The maximum loop range between the telephone and the power supply 
is 14 feet.
This power supply is intended to replace the MSP-1, 329A, 353A, 
1151A1/A2 and the 1151B1/B2 DC power supplies, the Definity Adjunct 
Power Kit (consisting of the KS-22911-L1/2 Plug-In Power Supply, 
D6AP-87 cord and 400B2 adapter), and the 2012D AC transformer.
The 1151C1 power unit has a green LED that shows the unit has power 
on the PHONE jack, pins 7 & 8 when AC power is applied.
The 1151C2 power unit has two LED's: a green LED that shows the unit 
has power on the PHONE jack, pins 7 & 8 when AC power is applied or 
running on battery and a YELLOW LED that shows the unit is charging 
the battery when illuminated. When blinking, the GREEN LED indicates 
that the unit is running on battery power.

The 1151C2 incorporates a new integrated feature that allows one to 
easily disable the output when the supply is disconnected from AC mains 
power. This allows storage of the power supply without rapid discharging 
of the internal sealed Lead-acid battery due to continued operation of the 
internal battery-voltage to output-voltage converter (henceforth referred 
to as the “boost converter”). After disconnecting the 1151C2 power 
supply from the AC mains following 1) normal use, or 2) periodic 
recharge maintenance of the internal battery, the user should do the 
following:

Locate the disable-switch access hole on the base of the 
1151C2 power supply. Insert a fine non-metallic object (such 
as a wooden or plastic toothpick) into the access hole and 
depress the recessed momentary contact switch. This 
operation disables the internal boost converter. Once the 
boost converter is disabled, all status LEDs will turn off (this 
may take a few seconds as the stored charge in the output 
filter capacitors is discharged). This operation should only be 
done when the power supply is to be stored or is to go 
through a period of non-use.

Note:

 One should 

not

 press the disable button when the supply is in 

active operation during a power failure. Once the boost converter disable 
button is pressed, the supply will no longer function until AC mains power 
is restored. When AC mains power is restored to the power supply, 
normal operation will resume.

Maintenance

The Avaya models 1151C1/C2 power supplies contain no user 
serviceable parts. To reduce the risk of electric shock, do not 
disassemble the product.
To clean the 1151C1/C2 power supply, first unplug the AC power cord 
from the wall receptacle (or other AC source) and disconnect all cords 
from the Line and Phone RJ45 jacks. Do not use liquid cleaners or 
aerosol cleaners. Use a damp cloth for cleaning.
Like all batteries, the internal Lead-acid battery of the 1151C2 power 
supply will self-discharge over a period of inactivity and must be 
periodically recharged to avoid damage. This is not a concern during 
normal supply operation, as the power supply will automatically recharge 
as needed. However, when stored and disconnected from the AC mains 
for an extended period of time, the battery should be recharged every six 
months to prolong battery life and avoid damage resulting from deep 
discharge. This may be done by simply connecting the power supply to a 
source of AC power and allowing the battery to charge for at least twelve 
hours. When battery charging is complete, if the power supply is to be 
placed back into storage or disconnected again from the AC mains, one 
should immediately disable the battery boost converter as outlined in the 
“Operation” section above.

Contents of the 1151C1 and 1151C2 Boxes 

Connecting the Power Supply

The power output is provided through a modular jack on the power 
supply. These jacks are labeled as follows:

The supply output is essentially isolated from earth ground and 
depending on the particular application, either output pin may be used to 
establish a reference potential. However, it is common in 
telecommunications applications to think of the supply output as nominal 
-48Vdc (pin 7) relative to a 0Vdc reference on pin 8.
The output jack, labeled “IP/DCP PHONE” is an 8-pin female non-keyed 
RJ45 jack that can accept D8W and RJ45 modular plug cables.
The input jack, labeled “LAN/DCP” is an 8-pin female non-keyed RJ45 
jack that can accept RJ45 modular plug cables, such as Cat5 (LAN) or 
Cat3 (DCP line) cables. A Cat5e cable fitted with RJ45 modular plugs is 
provided with the supply and may often be used in place of a D8W type 
cable if desired. 

1151C1

 

Quantity

Comcode

1

1151C1 Power Supply

700356447

1

4.26 m (14 ft) Cat-5e Network Cable 700204050

1

Installation & Safety Instructions

1151C2

 

Quantity

Comcode

1

1151C2 Power Supply

700356454

1

4.26 m (14 ft) Cat-5e Network Cable 700204050

1

Installation & Safety Instructions

IP/DCP
PHONE LAN/PBX 

Summary of Contents for 1151C1

Page 1: ...t a replacement This product should be operated only from the type of AC power indicated on the product label If you are unsure of the type of AC power being provided contact a qualified service perso...

Page 2: ...ist allerdings auch in gewissem Umfang IHRE Aufgabe Lesen Sie deshalb sorgf ltig die Hinweise auf dieser Seite Die an dieser Stelle gemachten Vorschl ge gew hrleisten den st rungsfreien Einsatz diese...

Page 3: ...este equipo visite http www avaya com support CONSERVE ESTAS INSTRUCCIONES VIGTIGE SIKKERHEDSINSTRUKTIONER FOR BRUGEREN Der er blevet taget n je hensyn til kvalitetsstandarder under produktionen af De...

Page 4: ...lergrootste aandacht besteed aan de kwaliteitsnormen Veiligheid is een zeer belangrijke factor in het ontwerp van elke product van Avaya Maar veiligheid is ook UW verantwoordelijkheid Lees de ondersta...

Page 5: ...SINSTRUKTIONER F R ANV NDAREN Tillverkningen av ditt str mf rs rjningsaggregat har skett med st rsta m jliga h nsyn till kvalitetsnormer S kerhet r en viktig faktor n r alla Avayas produkter utformas...

Page 6: ...t et laissez l entretien du personnel qualifi lorsque ces conditions sont pr sentes Le cordon de la prise d alimentation est endommag ou effiloch Un liquide a t renvers sur le produit Le dispositif a...

Page 7: ...assist ncia qualificado N o deixe que nenhum objecto fique apoiado sobre o cabo de alimenta o N o coloque este produto num local onde o cabo fique sujeito a maus tratos como por exemplo pessoas a cami...

Page 8: ...a ziemi lub zosta a uszkodzona obudowa Je li stwierdzono nieprawid owe funkcjonowanie urz dzenia Deklaracja zgodno ci Aby pobra Declaration of Conformity Deklaracj zgodno ci DoC dla tego urz dzenia na...

Page 9: ...an csokat Ezek a javaslatok lehet v teszik hogy a k sz l k minden el ny t kihaszn lhassa Az tmutat t rizze meg k s bb m g sz ks g lehet r FIGYELMEZTET S Ez a telefon NEM lakoss gi haszn latra szolg l...

Page 10: ...personal de servicio para solicitar un reemplazo Este producto s lo se debe operar con el tipo de energ a CA indicado en la etiqueta del producto Si no est seguro del tipo de energ a CA de que dispon...

Page 11: ...ort 1151C1 C2 TNV 3 TNV 2 TNV AC AC AC AC Avaya 1151C2 AC AC Declaration of Conformity DoC http www avaya com support KO HE Avaya 1151C1 C2 Avaya http www avaya com support 1151C1 C2 TNV 3 TNV 2 TNV A...

Page 12: ...Immunity IEC 61000 4 6 Power Frequency H Field Immunity IEC 61000 4 8 Voltage Dips Variations Immunity IEC 61000 4 11 Federal Communications Commission Statement Part 15 This device complies with Par...

Page 13: ...ck pins 7 8 when AC power is applied The 1151C2 power unit has two LED s a green LED that shows the unit has power on the PHONE jack pins 7 8 when AC power is applied or running on battery and a YELLO...

Page 14: ...option arrangement for IP Telephone models 4601 4602 4602SW 4610SW 5601 5602 5602SW and 5610SW Figure 7 shows the local powering option arrangement for IP Telephone models 4620 4620SW 4621SW 4622SW 46...

Page 15: ...15 Figure 1 Local Powering Arrangement for Model 7444 and for 2420 6416 6424 and CALLMASTER Telephones when Used with an Adjunct...

Page 16: ...16 Figure 2 Local Powering Arrangement for MERLIN LEGEND Telephones...

Page 17: ...17 Figure 3 Local Powering Arrangement for a PARTNER MLS CA24 DSS...

Page 18: ...18 Figure 4 Local Powering Arrangement for a PARTNER Remote Access Unit...

Page 19: ...Powering Option for 4606 4612 4624 IP Telephones DSS 4624 only optional Representative drawing not to scale Exact jack positions and orientations vary between specific models 1151C1 C2 IP DCP PHONE L...

Page 20: ...5602SW 5610SW IP Telephones 4610SW 5610SW Only 4610SW 5610SW Only These telephone models may also be powered over the network cabling from a central location using an IEEE Std 802 3af compliant switc...

Page 21: ...supplied with IP telephone Note The 4622SW does not have a handset but instead can support a second headset Note These telephone models may also be powered over the network cabling from a central loc...

Page 22: ...8 Local Powering Option for 4630SW IP Telephone optional Note This powering option does not apply to the Avaya 4630 IP Telephone It is valid for the Avaya 4630SW only 1151C1 C2 IP DCP PHONE LAN PBX C...

Reviews: