14
3-
Wire Power Cord Installation
•
Remove the Terminal Block Access Plate on the back
of range by removing the 1 fixing screws.
•
Assemble the strain relief in the hole on bracket.
•
Insert the power cord through the strain relief and
tighten.
•
Allow enough slack to easily attach the cord terminals
to the terminal block.
•
Remove the 3 wire terminal nuts and washers from
the terminal block.
•
Plug the terminal holes of power cord. The neutral or
ground wire of the power cord must be connected to
the neutral terminal located in the center of terminal
block. The power leads must be connected to L1 and
L2.
•
Plug washers and tighten nuts securely.
•
Assemble the Terminal Block Access Plate.
4-
Wire Power Cord Installation
•
Remove the Terminal Block Access Plate on the back
of range by removing the 1 fixing screws.
•
Assemble the strain relief in the hole on bracket.
•
Insert the power cord through the strain relief and
tighten.
•
Allow enough slack to easily attach the cord terminals
to the terminal block.
•
Remove the 3 wire terminal nuts and washers from
the terminal block.
•
Remove the ground strap from the frame of range and
terminal by removing its screw and cutting is as
shown.
•
Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to
the neutral terminal located in the center of terminal block. The ground wire of the power supply
cord must be attached to the frame of range by using the green colored grounding screw. The
power leads must be connected to L1 and L2.
•
Plug washers and tighten nuts securely.
•
Assemble the Terminal Block Access Plate.
Summary of Contents for ERU200P0W
Page 13: ...13...
Page 30: ...30...
Page 51: ...51...
Page 66: ...66 Rating label location ERU200P0W ERU200P3S ERU240P3S ERU240P0W ERU240P1B...
Page 68: ...68 Electric ranges VER 06122019 PRINTED IN CHINA...