Avanti DGR20P3S Installation Instructions Manual Download Page 6

6

 

 

 

 

INSTALLATION

 

 

PROXIMITY TO SIDE CABINETS 

 

1. 

This range may be installed adjacent to existing 36” (914 mm) 
high base cabinets ensuring a 20” (508 mm) opening width 
between the  cabinets.

 

Range dimensions: 

20” Wide Models 

24” Wide Models 

Width: 

19” 9/16  
(497 mm) 

Width: 

23 ½ 
(597 mm) 

Depth: 

23” 3/4  
(603.4 mm) 

Depth: 

23” 3/4  
(603.4 mm) 

Height: 

Without the backsplash 

MIN: 

35” 7/16 (900 mm)

 

MAX: 

36” 7/32 (920  mm)

 

Backsplash 
Height 

GR2011CW / GR2012CB / GR2013CSS 
GR2414CW / GR2415CB / GR2416CSS 
GRO20P0W / GRO24P0W 

5 ¼” 
134 mm 

DGR20P3S / DGR24P3S 

2” 
50 mm 
 

Gas line opening: 

 

Wall - 5” 57/64 (150 mm) from the floor; from the center to the rear left 
side of the range.

 

Grounded outlet:  

The electric cord with 3-prong ground plug has a length of 72” (1830 
mm). Grounded outlet should be located 5” 57/64 (150 mm) from the 
floor and from the center to the rear right side of the  range. 

 

2.  The range CANNOT be installed adjacent to sidewalls, tall 

cabinets, tall appliances, or other side vertical surfaces above 36” 
(914 mm)  high.

 

There must be a minimum of 3” (76 mm) side clearance from the 
range to such combustible surfaces TO THE LEFT above the 36” 
(914 mm) high countertop; or there must be a minimum of 11” 
13/16 (300 mm) side clearance from the range to such 
combustible surfaces TO THE RIGHT above the 36” (914 mm) 
high countertop.

 

IMPORTANT:  

One side (left or right) above the 36” (914 mm) high countertop 

must always be kept clear. Ensure a 20” (508 mm) opening 
width between the cabinets.

 

 

3.  The range CANNOT be installed adjacent to sidewalls, tall 

cabinets, tall appliances, or other side vertical surfaces above 36” 
(914 mm)  high.

 

There must be a minimum of 3” (76 mm) side clearance from the 
range to such combustible surfaces TO THE LEFT above the 36” 
(914 mm) high countertop; or there must be a minimum of 11” 
13/16 (300 mm) side clearance from the range to such 
combustible surfaces TO THE RIGHT above the 36” (914 mm) 
high countertop.

 

 

IMPORTANT: One side (left or right) above the 36” (914 mm) high 

countertop must always be kept clear. Ensure a 20” (508 mm) 
opening width between the cabinets. 

 

4.  The maximum upper cabinet depth recommended is 13” (330 

mm). Wall cabinet above the range must be a minimum of 30” 
(762 mm) above the countertop for a width of minimum 19” (482.6 
mm): it has to be centered with the range. Side wall cabinets 
above the range  must be a minimum of 18” (457 mm) above the 
countertop.

 

 

Summary of Contents for DGR20P3S

Page 1: ...de ANSI NFPA 70 latest edition and or local codes INSTALLATION IN MANUFACTURED MOBILE HOME The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3...

Page 2: ...ot try to light any appliance Donottouchany electricalswitch Do not use any phone in your building lmmediately call your gas supplier from a neighbor s phone Followthegassupplier sinstructions lf you...

Page 3: ...ess and which are known to the State of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in fuel or from fuel combustion make sure this appliance...

Page 4: ...ury or property damage Consult a qualified installer service agent or the gas supplier TOOLS NEEDED FOR INSTALLATION NOT SUPPLIED WITH THE APPLIANCE Screwdriver 2 Wrench T handle wrench Angled hexagon...

Page 5: ...gas at main supply B Disconnect AC powersupply C Disconnect gas line to the inlet pipe D Carefully remove the range by pulling outward CAUTION Range is heavy use care in handling 12 Electrical Require...

Page 6: ...aces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of 11 13 16 300 mm side clearance from the range to such combustible surfaces TO THE RIGHT above the 36 914 mm high coun...

Page 7: ...7 INSTALLATION PROXIMITY TO SIDE CABINETS GAS AND ELECTRIC CONNECTION...

Page 8: ...rews provided As shown in the diagram C Secure the backsplash from the bottom using the Philips head screws provided As shown in the diagram HOW TO LEVEL THE RANGE The range is equipped with 4 LEVELLI...

Page 9: ...gure below only rear right side it has to be fixed on the floor and on the rear wall by four 4 suitable screws not supplied 2 After fixing the anti tip bracket slide range into place Be sure the rear...

Page 10: ...o 16 for L P gas conversion instructions 1 Manual Shut off Valve The supply line shall be equipped with an approved shutoff valve This valve should be located in the same room as the range and should...

Page 11: ...the gas supply piping system at test pressure equal to or less than 1 2 PSI 3 5 kPa 3 Flexible Connections If local codes permit CSA design certified flexible metal appliance connector is recommended...

Page 12: ...must be replaced ALL REPAIR PART REPLACEMENTS AND CONNECTIONS MUST BE DONE BY AN EXPERIENCED LICENSED PROFESSIONAL WARNING Check the right positioning of the gas regulator The arrow on the back of th...

Page 13: ...the range Gas conversions are the responsibility of the dealer or end user SETTING THE PRESSURE REGULATOR STEP 1 STEP 2 STEP 3 Step 1 Open the regulator cover by turning the cover in a counter clockw...

Page 14: ...tion of the primary air The following process applies to the following models GRO20P0W GRO24P0W 1 Remove the pan supports 2 Remove the cooktop See the user s guide 3 Remove the screws which secure the...

Page 15: ...oved Please follow the instructions carefully a Open the door all the way b Lift the left and right hooks on the hinges c Hold the door firmly on each side d Gently close the door and lift upward once...

Page 16: ...screwing the front screw fig 23 b Gently suspend the burner as shown in figure 24 Take care as not to damage the wire to the ignition electrode as well as the thermocouple c Using a 7 mm box spanner u...

Page 17: ...Remove the left screw Insert the flat head screwdriver 2 5mm x 75mm Into the screw hole and turn the bypass screw clockwise to adjust the flame DO NOT OVERTIGHTEN 5 Replace the knob 6 Repeat for each...

Page 18: ...codes Recommended ground method For your personal safety this range must be grounded This range is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into...

Page 19: ...19 ELECTRICAL CONNECTION GR2011CW GR2012CB GR2013CSS GR2414CW GR2415CB GR2416CSS GRO20P0W GRO24P0W DGR20P3S DGR24P3S...