User Manual
14
Trouble Shooting
For Authorized Service Technicians Only!
CHECKING AND ADJUSTING MAIN BURNERS
The main burners should burn with a steady blue flame, and the inner cone of the flame from each port should be
about 3/4" long. The flame from each main burner should enter each heat tube without touching the front of the fry pot
or the sides, top, or bottom of each tube.
All units are adjusted at the factory. In case of problems in operation at initial installation, check type of gas and
manifold pressure and compare with information listed on the serial plate.
A mill voltage circuit diagram is located inside the front door of the fryer, and also on page 19.
Yellow Tips
(too little air or too much gas)
Blowing or Lifting Tips
(too much air)
Normal Flame
NOTICE
Warranty will be void and the manufacturer is relieved of all liability if:
(A) Service work is performed by other than a qualified technician (see page 30 for details)
OR (B) Other than approved Avantco replacement parts are installed.
WARNING
Adjustments and service work may be performed only by a qualified technician who is experience in,
and knowledgeable with, the operation of commercial gas cooking equipment. However, to ensure your
confidence,contact your Avantco Service Representative for liable service, dependable advice or other
assistance, and for genuine factory parts.
!
!
Summary of Contents for 177FF300L