7) Constant Temperature

When the water level reaches to the point when it covers all jets, you can turn on the heating 
function by pressing the        button on the display panel or remote control. You can turn the 
function OFF by pressing the same button one more time. When the symbol of constant 
temperature is flashing or when you press             button, you can adjust the temperature of 
water with this                      button. Setting range is 15-45 degrees, please note when the 
temperature is equal to the set temperature or higher, the function will not start working.

8) Ozone Treatment

By pressing       button on the panel or remote control you will start the ozone function and it will
last for 15 minutes. After those 15 minutes the function will stop automatically. Pressing it once 
again while the timer is still on will turn off the function earlier than after 15 min. You can see on
the display how much time is left when the function is on.

9) Waterfall 

Pressing the       waterfall button on the display panel or remote control will turn on the waterfall
function and start to fill up the water. The function will stop automatically when the bathtub will 
be supplied with enough water.  You can stop the function earlier at another water level by 
pressing the same button once again.

10) Automatic Cleaning Function

After each shutdown, more or less after 10 minutes, the system will start self-cleaning function 
and it will stop automatically after 2 minutes. 

Dimensional Drawing

13

Summary of Contents for MONACO

Page 1: ...ches do not hit or rub against the bathtub with a hard object 4 To avoid stumbling please pay attention to the drop height while entering the bathtub 5 Please pay double attention in case of wet surface with soapsuds 6 Do not use any acidic and strong alkaline acetone ammonia detergent as well as any other which can cause corrosion Clean it with a soft cloth and a mild detergent suitable to use on...

Page 2: ...Please use tools to open this parcel Make sure all accessories are inside the packing 2 ...

Page 3: ...s and procedures 3 User should install an electric leakage protector on the power supply Power lines must be checked and connected with a good ground line The section of the electrical wire should not be less than 2 5m2 The power supply appliance should be in accordance with the National Safety Standard 4 WARNING While using electrical devices basic precautions should be followed by user 5 DANGER ...

Page 4: ...Installation of water supply Installation Process 4 ...

Page 5: ...s need to install the faucet according to basic procedures after that connect the cold hot water hose to the corresponding water supply tube which should be in the shelter of the bathtubs back A Waterfall B Handheld Shower C Switch for Shower and Faucet D Temperature Adjuster Installation of Bathtub 5 ...

Page 6: ...1 Please lay the bathtub upside down and wrap the drainer with thread PTFE tape then screw the drainer Please see the drawing below Installation of Bathtub 6 ...

Page 7: ...d shower after that connect to the water hose intake 3 Adjust the tub feet to make it horizontal Move the bathtub to the wall corner Put the drainer to the sewer and seal the drainer with a sealant Seal the gap between the bathtub and the wall with sealant to avoid water leakage 7 ...

Page 8: ... head 3 Do not press the water pump switch unless the water level in the bathtub is above the jets position 4 Use air regulator to adjust the massage power 5 Rotate the handheld shower to adjust the massage effect 6 Light turns on and changes automatically when you turn on the pump It turns off when you turn off the pump 7 Press pneumatic switch turn off the pumps and drain the water out after use...

Page 9: ...switch is set on OFF Problems with power supply plug not enough power to supply the bathtub Water pump faulted Turn on the power supply and connect the leakage protector Clean the water pump impeller Press the water pump switch Check the plug in case it is turned off if yes plug it back in Repair or replace the water pump MASSAGE POWER CANNOT BE ADJUSTED Electric voltage problem Air regulator swit...

Page 10: ...d run the massage system for 3 minutes Finally clean the bathtub one more time after stopping the pump and draining off the water Precautions 1 The installation should be carried out by a qualified technician and should be done according to the manual 2 The bathtub electric parameter should be equivalent with the National Safety Standards There should be electric leakage protector on the power sup...

Page 11: ...mp state display E Remote control receiving window F Ozone status display G Constant temperature state display AA 07 Remote Control Description 1 ON OFF 2 Waterfall button 3 CD connector button 4 Volume up or function adjustment button upwards 5 Volume down or function adjustment button downwards 6 Telephone button 7 Water pump button 8 Ozone pasteurize 9 Radio 10 Radio channel switching and stori...

Page 12: ...ther frequency you need to press the FUN button which will go into search status By using and buttons you can pick the frequency by yourself by holding them for a longer period of time egg 5 seconds it will go into automatic search of the nearest frequency To save the frequency channel please press M button to store it Pressing button twice in a row will switch from one saved channel to another It...

Page 13: ...t the ozone function and it will last for 15 minutes After those 15 minutes the function will stop automatically Pressing it once again while the timer is still on will turn off the function earlier than after 15 min You can see on the display how much time is left when the function is on 9 Waterfall Pressing the waterfall button on the display panel or remote control will turn on the waterfall fu...

Page 14: ...14 ...

Reviews: