SMA-X8I, REV-SA03 User
’s Manual
8 SMA-
X8I, REV-SA03
User’s Manual
Non-Operation
3 Sweep
:
1 Oct/ per one minute. (logarithmic)
4 Test Axis : X,Y and Z axis
5 Test time :30 min. each axis
6 System condition : Non-Operating mode
7. Reference IEC 60068-2-64 Testing procedures
Bump Test
1. Wave form
:
Half Sine wave
2. Acceleration Rate
:
10g for operation mode
3. Duration Time
:
11ms
4. No. of Shock
:
Z axis 1000 times
5. Test Axis: Z axis
6. Operation mode
7. Reference IEC 60068-2-29 Testing procedures
Test Eb : Bump Test
OS Information
Android 10
Linux Yocto sumo 2.5 (Default)
REV-SA03
System
SMARC
SMARC V2.1
Compatible with Avalue and other SMARC modules
CPU Modules. (82 x 50mm)
External I/O
Connector
1 x Power Key
1 x Reset Key
1 x DC Jack
1 x USB 2.0 Type A
1 x USB 3.0 Type A
J3 (reserved design for USB3.0)1 x USB Type C
1 x Giga Ethernet
1 x Headphone
1 x Micro SD Socket
1 x SIM Socket
Internal I/O
Connector
1 x Mic Phone 2P Header
1 x Speaker (Left/Right Channel) 2P Header
1 x RTC-Battery
(
CR2032
)
1 x M.2 Key E for WIFI /BT
1 x M.2 Key B for LTE
1 x M.2 Key M for Storage
1 x A53 Core Debug connector (UART)
1 x M4 Core Debug connector (UART)
1 x BackLight 4P Header
Summary of Contents for REV-SA03
Page 13: ...User s Manual SMA X8I REV SA03 User s Manual 13 2 Hardware Configuration ...
Page 26: ...SMA X8I REV SA03 User s Manual 26 SMA X8I REV SA03 User s Manual 3 Mechanical Drawing ...
Page 27: ...User s Manual SMA X8I REV SA03 User s Manual 27 SMA X8I Unit mm ...
Page 28: ...SMA X8I REV SA03 User s Manual 28 SMA X8I REV SA03 User s Manual REV SA03 Unit mm ...