User’s Manual
ECM-5510 User’s Manual
101
27. Wrong Board In Slot
PLEASE RUN EISA CONFIGURATION UTILITY
The board ID does not match the ID stored in the EISA non-volatile memory.
Note:
When either of these errors appears, the system will boot in ISA mode,
which allows you to run the EISA Configuration Utility.
28. FLOPPY DISK(S) fail (80)
→
Unable to reset floppy subsystem.
29. FLOPPY DISK(S) fail (40)
→
Floppy Type dismatch.
30. Hard Disk(s) fail (80)
→
HDD reset failed.
31. Hard Disk(s) fail (40)
→
HDD controller diagnostics failed.
32. Hard Disk(s) fail (20)
→
HDD initialization error.
33. Hard Disk(s) fail (10)
→
Unable to recalibrate fixed disk.
34. Hard Disk(s) fail (08)
→
Sector Verify failed.
35. Keyboard is locked out - Unlock the key.
BIOS detect the keyboard is locked. P17 of keyboard controller is pulled low.
36. Keyboard error or no keyboard present.
Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys
are being pressed during the boot.
37. Manufacturing POST loop.
System will repeat POST procedure infinitely while the P15 of keyboard controller is pull
low. This is also used for M/B burn in test.
38. BIOS ROM checksum error - System halted.
The checksum of ROM address F0000H-FFFFFH is bad.
39. Memory test fail.
BIOS reports the memory test fail if the onboard memory is tested error.
Summary of Contents for AMD Geode E2047551001R
Page 21: ...User s Manual ECM 5510 User s Manual 21 2 Hardware Configuration ...
Page 22: ...ECM 5510 22 ECM 5510 User s Manual 2 1 Product Overview ...
Page 64: ...ECM 5510 64 ECM 5510 User s Manual 3 BIOS Setup ...
Page 93: ...User s Manual ECM 5510 User s Manual 93 5 Measurement Drawing ...
Page 94: ...ECM 5510 94 ECM 5510 User s Manual Unit mm ...
Page 96: ...ECM 5510 96 ECM 5510 User s Manual Appendix B AWARD BIOS POST Messages ...