Preventive Maintenance
9.2
Brewer Assembly
Preventive Maintenance (PM): Yearly or every 25,000 coffee cycles
The brewer is the heart of the equipment and is responsible for the taste of the beverage. It needs to
be replaced or refurbished to maintain the quality of the beverages served. We recommend having your
brewer assembly replaced every 25,000 coffee cycles.
Contact 1-800-561-6162 for parts and additional information.
Inspection
The following are signs of the vacuum is not functioning adequately and that your brewer may be due
for preventive maintenance:
· if the seal is damaged;
· if air gets into the cylinder and creates bubbles in the coffee;
· if there are coffee grounds in the delivered product;
· if the spent coffee grounds remain wet.
Screen and Seal
Cylinder
Brew Chamber
Piston Seal