8.6.2 Soluble Canisters
Sanitizing the whipping assemblies
Frequency: Weekly or every 200 cycles
This will prevent residue from attaching to the sides of the funnel.
Caution! The rinse water is HOT
1. Place a Large cup or other suitable container below the
dispensing nozzle to catch the HOT rinse water;
2. Toggle the ingredient switch to Off (SW5);
3. Order several beverages for the hot water to flow through the
system;
4. Toggle the ingredient switch back to ON;
5. Order a large beverage to confirm that all parts or switches have
been replaced.
Removing whipping assembly for cleaning
Frequency: Weekly or every 200 cycles
If there is residue, remove the assembly for manual cleaning under hot water:
1. Remove the tube from the base;
2. Lift off the funnel and twist off the whipper chamber, remove propeller,
whipper base and clean all parts and gaskets with hot water;
3. Rinse thoroughly under hot water and use tube brush if necessary for
tubing area;
4. Air dry completely;
5. Reinstall all parts in the reverse order.
6. Order a large beverage to confirm that all parts or switches have been
replaced.
Removing canisters for cleaning
Frequency: Monthly or every 1,000 cycles
To ensure a consistent product quality, we recommend removing and
emptying the canisters on a monthly basis. This will ensure that the
product does not adhere to the walls of the canister.
1. Unlock the door;
2. Remove the top cap of the machine;
3. Pull the canister through the top of the brewer to disengage it
from the motor and transmission;
4. Clean and sanitize under hot water and air dry completely;
5. Reinstall all parts and reload products in the reverse order.
6. Order a large beverage to confirm that all parts or switches have
been replaced.