OPERATING THE REMOTE CONTROL
Power
Use the
Power button to turn the portable air conditioner on and off.
By default when you first use the power button, the unit will begin to operate in cooling mode and the
front panel will be illuminated in blue. The unit will remember the last used mode / settings if you shut
down and restart.
Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used
mode / settings once power is restored. The compressor will restart after 3 minutes.
Cooling Mode
Cooling mode cools and dehumidifies the air. If the ambient temperature drops below the temperature
you selected, the compressor turns off and the unit functions with the fan only. When the temperature
rises above the temperature you selected, the compressor turns on again. The front panel lights will be
blue. Whether your desired temperature can actually be reached depends on the ambient conditions.
The room temperature remaining above the set temperature is normal.
To operate the unit in cooling mode:
1.
Make sure the power cord is plugged into a power outlet.
2.
Press the
Power button on the remote control.
3.
Press the
Mode button until the
cooling indicator is selected.
4.
Select the fan speed by using the
Speed button.
5.
Set the thermostat by using the
Up and
Down buttons. The thermostat is adjustable
between 61° F - 89° F in one degree increments. You can switch between Fahrenheit and Celsius by
pressing the
button.
Dehumidifying Mode
During the Dehumidifying mode, the unit will condense water out of the air and exhaust it through the
exhaust hose. The ambient temperature in the room will probably drop by a few degrees while using the
Dehumidifying mode. The front panel lights will be yellow.
To operate the unit in dehumidifying mode:
1.
Make sure the power cord is plugged into a power outlet.
2.
Press the
Power button on the remote control.
3.
Press the
Mode button until the dehumidify indicator is selected.
NOTE: The exhaust hose must be
used in Cooling mode in order to
cool a room.
Note: The exhaust hose must be used in Cooling mode in order to cool a room.
Notes: If the room temperature is below 77° F, the fan will always run on low speed in this mode. If you do
not use the exhaust hose in Dehumidify Mode, you must manually drain the water from the unit.