9 3 5 0 8 1 1 7
Installation Warnings
! Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
! This heater must be installed by a qualified installer who has gone through a training program for the
installation of direct vent gas appliances.
! This appliance must be installed in accordance with all local codes, if any; if not, follow current ANSI
Z223.1 or NFPA 54 in the USA or the current CGA B149 in Canada.
! In Manufactured or Mobile Homes this appliance must be installed to the applicable Mobile Home
Standards: CAN/CSA Z240 MH, the Manufactured Home Construction and Safety Standard, Title 24
CFR, Criteria for Manufactured Home Installations, Sites and Communities, and/or ANSI/NFPA 501A.
This appliance may be installed in Manufactured Housing only after the home is site located.
! This appliance is designed for natural gas or propane (LP). Check the sticker on top of the gas control
valve.
! All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from
outside the living-area structure.
! Notify your insurance company before hooking up this appliance.
! The requirements below are divided into sections - all requirements must be met simultaneously.
Packing List
• Cedar Stove • Log Set, Coals • Propane Conversion Kit • Owner's Pack
Installation Preparation
HINT:
If converting to LP, convert the appliance prior to installation.
HINT:
Install the logs last - they are fragile.
HINT:
When determining the location of the stove, locate the wall studs (for horizontal penetrations)
and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position
slightly to ensure the vent does not intersect with a framing member.
HINT:
Fumes and smoke from the paint curing and oil burning off the steel may occur the first time
you start this heater. This is normal. We recommend you open windows to vent the room.
Stove Clearances
10"
Min.
5" Min.
Straight
Installations
Corner
Installations
With this clearance, the vent
is 10-1/4” from the wall.
5" Min.
Measure
Clearances to
the Stove Top
Measure
Clearances to
the Stove Top
45°
With this clearance
the vent is 7-3/4” from
the back wall, 18”
from the side wall.
Mobile Home Requirements
•
When the stove is installed in a mobile home, it must be bolted to the floor and the
appliance grounded (use the blower with a grounded circuit or other suitable grounding
method - current ANSI/NFPA 70 or CSA C22.1).