Avallon Portable Air Conditioner
10
1. Connect the included water line to the unit. You will need to
attach the quick connect adapter on the end of the water line
to the back of the unit.
2. Run the remaining water line into the exhaust hose through
the opening in the exhaust hose adapter. This adapter
MUST be installed on the exhaust outlet of the unit. If the
adapter is not installed in this position you will need to adjust
the adapters. Run the excess water line into the cavity of
the exhaust hose.
3. Connect the mist nozzle to the end of the water line. Ensure
the water line is attached securely to the mist nozzle.
4. Attach the mist nozzle to the grated adapter. Make sure the
mist nozzle is directed to mist outside of the window and not
back into the exhaust hose.
The unit will now automatically mist any excess water to the
outside. Installing the mist system in the exhaust hose ensures all
of the moisture is pushed completely away from the window.
NOTE: It is recommended to
attach the misting nozzle in a
vertical position on the grated
adapter.
NOTE: The water line quick
connect includes a trigger to
let the unit know a water line
is attached. The unit will not
pump water out of this
drainage hole unless the
quick connect water line is
attached.
CAUTION: The water line will
contain some water if the
pump has been in use. If you
are going to detach the water
line from the unit be sure to
keep the end of the water line
elevelated once it is detached
to avoid water spilling. Drain
the remaining water in the
water line if you are preparing