AV-GAD Eye-Spy II Installation Instructions Manual Download Page 9

9

 

 

 

Walk Test

 

 
Replace the front cover during the walk test. 
Apply power and wait at least two minutes for 
the detector to stabilize. 
The LED is viewed through the detector lens.  
Walk through the entire protected area and 
observe the LED to confirm full coverage.  If 
the swivel is used, adjust it when necessary. 
To prevent false alarms adjust sensitivity at 
minimum and pulse at mode 3 setting (factory 
default is mid range). 
 
When adjustment is complete, tighten the PIR 
cover screw. For Eye-Spy II with swivel 
bracket, refer to figure 3; tighten the two 
adjustment screws. 

 

WARNING: Test this alarm 

product at least once a week. 

 
Av-Gad Limited Warranty

 

 
Av-Gad Systems Ltd. and its subsidiaries and affiliates 
(“Seller”) warrant its products to be free from defects in 
materials and workmanship under normal use for 12 months 
from the date of sale.   
Because Seller does not install or connect the product and 
because the product may be used in conjunction with products 

Summary of Contents for Eye-Spy II

Page 1: ...Installation Instructions Version IV Built In EOL mode removed Eye Spy II Standard w o bracket Eye Spy II PRO With bracket Eye Spy II Quad Pet With bracket Eye Spy II Curtain w o bracket Item 4773...

Page 2: ...Eye Spy II in a way that the intruder will cross the infrared beam pattern Do not mount the unit in direct sunlight windy place near airflow high voltage lines or close to heat sources Front Cover Re...

Page 3: ...ides optimal coverage The Eye Spy II special optics provides optimal covering and range when mounted at 1 60 3 30 meter 5 to 12 ft height PCB vertical adjustment not required The highest installed pro...

Page 4: ...To prevent false alarm caused by insects and air stream seal the cable entry knockout and holes that are not in use Mounting With the Swivel Bracket The swivel bracket is used for wall mounting only f...

Page 5: ...swivel bracket channel Seal this hole after installation Install the bracket to wall after inserting the cable first remove the Pan Screw from the bracket and tighten this screw from the detector base...

Page 6: ...l block at the PIR board as shown in figure 4 Wire the Tamper switch to a separate zone programmed at alarm panel as tamper or 24H type 12V DC Power supply inputs ALARM N C contact MOS relay TAMPER N...

Page 7: ...he most hostile environment Avoid installing the Pet PIR in front to stairway or furniture for preventing the pet to jump in front of the detector and cause false alarm CURTAIN TYPE Typical mounting h...

Page 8: ...s at position 1 Position 3 is recommended to prevent false alarms lower sensitivity Factory default is no pulse count EOL MODE Jumper Settings Starting Sep 2006 the EOL option removed PET MODE Eye Spy...

Page 9: ...ode 3 setting factory default is mid range When adjustment is complete tighten the PIR cover screw For Eye Spy II with swivel bracket refer to figure 3 tighten the two adjustment screws WARNING Test t...

Page 10: ...mages or delay Seller does not represent that its products may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwi...

Page 11: ...is product should be tested at least once a week Standards The EYS II Conforms to European Union EU Electro Magnetic Compatibility EMC Directive number 89 336 EEC amended by 92 31 EEC 93 68 EEC The CE...

Page 12: ...5 amps 24V DC N C Range 15 meters 20 C 3 m high Size without swivel 7 7 x 6 6 x 3 9 cm 3 0 x 2 6 x 1 5 Swivel Bracket Adjustment Horizontal tilt 25 Vertical pan 5 15 Optical Filtering White light pro...