When the call ends, the three short beeps sound at the keypads. When the user code is 
in  process,  the  keypad  display  shows  a  line  for  each  code  number  entry  (disclose  the 
code), then each DTMF number pressed show the received number.  
History log: Each call, confirmed by a valid user code, is recorded in the events history. 
Each "Arming/Disarming" is recorded in the events history. 
 

Notes: 1. The keypad buzzer or other loud sounds may jam your DTMF entries, in case the 
keypad is close to your DTMF telephone, during testing disable the buzzer.  
2.  When  entering  the  DTMF  commands  wait  for  “quiet”  period,  if  entering  commands 
during  the  system  confirmation  tunes,  or  other  tunes  the  panel  may  miss  the  DTMF 
entries. 

 
The panel calls the user during alarm 

 
When the control panel calls the user during alarm, it will first generate the siren sound 
for about 30 seconds (to shorten this feature at address 045 “Tel. Mi. call Time”, to 30, 
as default is 60 seconds). The siren sound will stop ten (10) seconds before the end of 
the  call  and  a  greeting  tune  will  be  sounded,  after  the  greeting  tune  enter  your  code 
followed  by  #.  To  stop  the  dialer  enter  6#,  to  get  panel  status  enter  7#,  to  disarm  the 
panel enter 2#. Press 9# to end the process. To arm the system press 1 # 
The control panel will answer the call after the number of rings programmed at address 
054 (or following the “bypass answering machine" procedure).

  

 
4.4 DTMF Commands 

Each command must be followed by the '#' key (Enter) in the remote phone. The control 
panel  waits  4  seconds  between  the  keys  typed.  When  this  time  expires,  previous  keys 
input will be discarded. 
The key '*' cancels previous input. It’s recommended to start with "learn" function [8X #] 
to identify the various confirmation tune. 
The commands: 
[0 XX #] - 

Bypass zone

 (# is the Enter key), XX is Bypassed zone 01 to 32 

To clear all bypassed zone: 099 #  
The zone bypass command is valid only when the system is in Disarm mode, not valid in 
Alarm mode. 
[1 #] - 

Arm control panel

. The control panel will be armed even with open zones. After 

the  arming,  a  confirmation  tune  followed  by  an  "armed"  tune  will  be  sounded  ("Armed" 
tune: Short beep followed by a long tone). 
The  user  can  wait  a  few  seconds  to  be  sure  that  no  alarm  has  been  caused  by  open 
zones. In this case, an Alarm tune (siren sound) will be sounded. 
[2  #]  -

  Disarm  control  panel

.  The  control  panel  will  be  disarmed.  A  confirmation  tune 

followed by a "disarmed" tune will be sounded ("Disarmed" tune: Five short beeps). 
[31 #] - 

Activates A1

 output for 4 seconds (enabled by programming 122) 

[33 #] - 

Activates SLO

 output for 3 seconds (enabled by programming 133) 

[50 #] - 

Deactivates A2

 output to stop Listen In (enabled by programming 128) 

[51 #] - 

Activates A2

 output for Listen In (enabled by programming 128) 

[6 #] - 

Stop dialer.

 The dialer will stop calling the programmed telephone numbers. This 

will affect only the current dialing process. A new alarm will re-start the dialer. 

Summary of Contents for EasyLoader AV-4008 Pro

Page 1: ...m Control panel Communicator 8 zones PSTN SMS Enabled Installation and Operation Large Manual Version 1 05 Preliminary Edition I This product is subject to continuous enhancements and therefore specifications may be changed or altered without prior notice Item 4764E A3BKE Rev 03 04 May 2018 ...

Page 2: ...g 15 3 2 SVM Synthesized Voice Module SVM 40 and SVM 42 16 3 3 Answering Machine Bypass 16 3 4 Telephone Line Test 17 3 5 Contact ID Format 17 3 6 ID Codes for Communicator 17 3 7 Remote Up and Download 17 4 Remote DTMF and remote Arming 18 4 1 Remote Key and Wireless Arming Disarming Passive arming 18 4 3 Remote Access via DTMF 19 4 4 DTMF Commands 20 5 System Codes 21 5 1 Description of main cod...

Page 3: ...rogramming locations 35 8 Programming Sheet AV 4000 Dublo Version 1 05 36 9 Step By Step Programming 40 9 1 Reset System to Default Programming 42 10 Powering Up Wiring Diagram 42 10 1 Before Powering Up 42 11 Technical Specifications AV 4009 AV 4016 44 12 Troubleshooting 45 13 Wiring Diagram AV 4009 48 14 Wiring Diagram AV 4008 49 15 Wiring Diagram AV 4016 50 ...

Page 4: ...terminals to V This will simulate a system with all zones looped out through closed switches The alarm is supplied already programmed with an average list of settings default and can be used straight away a few of the program locations may have to be changed to suit the actual sensors and output devices used The AV 4044 Pro AV 4008 Pro AV 4009 AV 4016 Dublo are compatible with LCD keypads don t us...

Page 5: ... software version check procedure Keypad AV 707 short description Figure 1 AV 707 LCD keypad description Common Terms in this Manual SHUNT and BYPASS are interchangeable terms Program Mode Enables features programming Programming is displayed alarm is disabled Use Mode System is disarmed and not in alarm or program mode AV 706 and or AV 707 is identical in operation ...

Page 6: ...use device included as a series element in electric circuit In response to an over current it protects the circuit by going from a low resistance to a high resistance state that reduces the current to a level that s safe for the circuit elements The change in resistance is the result of a rapid increase in the temperature of the device Like traditional fuses Electronic Fuse devices interrupt the f...

Page 7: ...00 meters using 0 5 mm 2 wires EOL mode wiring is highly recommended Note Zone and Sector are interchangeable terms in this manual An EOL zone will report Tamper alarm in case of zone shorting if it has been EOL programmed For connecting N O zones programming is required refer to address 304 Do not connect few sensors to one zone in EOL mode Av Gad Panel V Z4 Eye Spy II PIR Colors 2 2K Colors 4 7K...

Page 8: ...sor contacts relay the other wire in series with 4 7K resistor and other contacts Av Gad 3000 Series panel V Z1 Eye Spy II PIR 2 2K 4 7K Notice wires to V Colors 2 2K Colors 4 7K Red Red Red Yellow Purple Red Figure 2 3 EOL mode zone wiring The 2 2K resistors are wired with alarm zones the 4 7K are wired with the Tamper zone Some countries are used to different double pole wiring as shown in figur...

Page 9: ...tor 2 2K or 4 7K 0 25 or 0 5W inside the detection device e g PIR Magnetic Switch Figure 2 2 EOL mode PCB jumper settings Maximum zone wiring length is 200 meters using 0 5 mm 2 wires EOL mode wiring is highly recommended Note Zone and Sector are interchangeable terms in this manual An EOL zone will report Tamper alarm in case of zone shorting if it has been EOL programmed For connecting N O zones...

Page 10: ... board on the left side of the AV 4016 board as the drawing shows Use two screws to tighten the AV 816 The AV 208 fits the AV 4009 Dublo locate the board in the left side f the board refer to the wiring diagram last section in the manual Connection Make sure power and battery are disconnected Plug the wires connector of AV 816 to J1 socket at the AV 2016 refer to figure 2 5 drawing 2 5 Keypad Wiri...

Page 11: ...r than 100 meters keypad wiring contact manufacturer s consultant For AV 706 707TP keypad with tamper run five 5 wires Connect the TMP terminal to a 24H or Tamper zone Power at Keypad should be a minimum of 11 5 Volts IMPORTANT Never run Keypad wires alongside telephone wires high voltage wires or transmitting antennae Wire the keypad wires separately and not in same cable with other devices telep...

Page 12: ...ssued by the siren differs according to the type of zone Bell Mode converts Siren outputs into 13 6V DC outputs no sound is issued Bell mode is applicable for driving self powered sirens or bells or combined sirens and strobes Figure 2 7 W iring sirens to control panel Output of 13 6V DC is issued at Bell mode It s recommended to use Bella sirens series In Bell mode connect only sirens which conta...

Page 13: ...rrent Strobe Light Xenon that consumes up to 100 mA Do not connect plain relays sirens or similar loads to the outputs Home Automation feature Momentary activation of A1 output for three seconds via any DTMF telephone command address 074 2 See drawing sample In case other features are selected for the same output this feature is not applicable Figure 2 8 W iring remote indication output to protect...

Page 14: ... or specific models to fit 2 11 Back Up Battery Make sure to connect the Battery in the correct polarity The system s Red wire is the positive pole and the Black wire is the negative pole The battery will provide power back up in case of AC power failure Connect back up battery to ensure proper operation of the system Recommended battery 7 Amperes per Hour AH 12V sealed lead acid type Battery type...

Page 15: ... line if a device is in parallel with the alarm panel this may grab the call first like a message answer fax during remote up and download and remote DTMF Don t connect fax or answering machine in parallel on the same telephone line In AV 4009 4016 GSM if phone numbers programmed system dials them via PSTN send SMS via GSM Dialing via central phone system PBX enter 9 get line hold down 0 pause tha...

Page 16: ...crophone For interfacing the SVM to your panel refer to the SVM manual AV 4000 GSM panels are not compatible with SVM 40 or SVM 42 The SVM is a digital message source in Series 4000 Alarm Control Panels telephone dialers or in other applications The SVM supplied audio is capable to drive audio amplifier message center automatic dialer or other device When connected to series 4000 program the SVM t...

Page 17: ...main central station Tel Number and Tel 3 address 020 is for 2 nd central station reporting or as backup to the same CS Contact ID Format known also as Ademco Express is the fastest to program and easiest to use communicator format for central station with communication speed achieved by the DTMF signaling When using Contact ID format program only Central Station telephone numbers and the subscrib...

Page 18: ...eld using arrows when possible the TAB key forward shift TAB backward ALT key highlighted letter Confirm input in text fields by hitting the ENTER return key In order to select the required field hit the highlighted digit or letter Full instructions and latest features are enclosed in the EasyLoad software diskette Check the latest Windows EasyLoad Local Up and Download via PC AV 232 adapter requi...

Page 19: ...TMF General Description Program address 109 to enable DTMF remote control Verify that your PSTN line support DTMF dialing other important issue is that PSTN line is at good condition Adding GSM module or low quality ADSL filter may interfere DTMF commands DTMF commands are available when the panel call your phone or by calling the panel The DTMF remote control functions Check the status of the con...

Page 20: ...ress 054 or following the bypass answering machine procedure 4 4 DTMF Commands Each command must be followed by the key Enter in the remote phone The control panel waits 4 seconds between the keys typed When this time expires previous keys input will be discarded The key cancels previous input It s recommended to start with learn function 8X to identify the various confirmation tune The commands 0...

Page 21: ... Code also called Owner Code Use code No 1 to program a new user code Upon setting new Arming Disarming code default user code 1234 automatically replaced 2 Code number 7 for access control requires programming Arm Disarm code No 7 activates the ON output which is used for such functions as opening an electric lock Code number seven 7 is operative during ARM and DISARMS modes confirmed by seven sh...

Page 22: ...er the number same for telephone numbers 2 3 4 5 4 Installer Programming mode Code change 1 Hold down key 8 Program while the four LEDs are blinking enter 1994 default code P displayed 2 left most LEDs blinking 2 While system is in installer program mode 3 Enter 099 u displayed press 33 than the new code U big U displayed to confirm 4 New code displayed for conformation System reverts to Installer...

Page 23: ...f used to open a door If Auto Arming selected and Group Bypass consider Group 2 is bypassed at auto arming Passive auto Arming is activated if all zone been close for XX 05 to 99 minutes the XX time is programmable at address 098 5 7 Restore default codes Restore default codes feature requires programming at 106 Disabling the feature prevents codes restore To restore the factory default codes Powe...

Page 24: ...and disables the function Chime mode is confirmed by c display on keypad 6 Telephone Key 6 DIALER TEST FOLLOW ME PROGRAMMING Test is performed in DISARMED mode Function Via AV 706 707 LCD Keypad Displays Programmed Follow Me Telephone Number Without Dialing Hold down key 6 Follow Me telephone number programming Hold down key 6 then hold down 6 again Programmed Telephone number Verification Display...

Page 25: ...e beeps indicate zone closing Quit Fault Find mode by arming the system 8 Program Key 8 PROGRAM Key 8 accesses Program mode and user code programming followed by password 9 Reset Key 9 RESET Reset performs the following functions 1 Cancels last Keypad entry 2 Stops the communication test triggered by hold down key 6 3 Activates output 2 for resetting the Smoke Detector requires programming 4 Reset...

Page 26: ...st alarm sequence 2 0 Shunt and 0 Shunt Detailed Events History requires programming Hold down key 0 and again hold down key 0 to display up to 36 events including System opening and closing by user number opening or closing time alarming zone and AC fail By holding down key 0 Shunt twice 3 LEDs start blinking to indicate a special operation mode The events are displayed from the most recent event...

Page 27: ... means Factory default In programming mode enter 200 than the required function as detailed below Location Function 200 and Display control panel type software version 200 and 04 Erase reset the events history 200 and 05 Restore all codes to factory default 200 and 08 Set all zones to none EOL cancels double zones 200 and 10 SMS Not available 200 and 11 SMS Not available 200 and 12 Not available 2...

Page 28: ...led alarm history use the downloaded from panel to remote computer History queue log of up to 250 events are displayed only 99 at panel keypad and in the EasyLoad PC software 4 0 Shunt and 1 Siren Display and Setting of System Time Hold down key 0 and then hold down key 1 3 LEDs will blink Wait for the display of system time in 4 digit format To set new time hold down key 0 and then hold down key ...

Page 29: ...ATION SOUNDER RESPONSE Pressing of any key Short confirmation beep Power up Six beeps Hold down functions Long confirmation beep Faulty programming input Long beep E display Delayed Zone triggering Three long beeps Exit delay starting if programmed Warning beeps until the delay is over Completion of Arm Disarm programming code One long confirmation beep Programming Telephone numbers Two confirmati...

Page 30: ... AV 4009 AV 4016 Blink slow Warning before Fire alarm Blink fast During and after Fire alarm Note At alarm time Troubled Zones are displayed at the Keypad Red ARMED ALARM Indicator Lights up when system is armed blinks after an alarm is triggered at any zone Blinking indicates alarm history in memory Green STATUS Indicator Blinks when zone s are troubled and remains lit as long as zones are clear ...

Page 31: ...med mode rapid blinking indicates system restored after AC Power Failure mode During programming Follow Me Telephone Number three flashing LEDs indicate to enter a new telephone number Four LEDs Flashing Upon holding down key 8 the system is ready for code to be entered Same LED indication when code is expected for Bypass via code ...

Page 32: ...r and minutes 036 def 00 01 Auto Arming Hour and minutes 006 def 00 00 Telephone numbers There are 13 telephone numbers 16 digits each No limitation on the numbers of pauses in a telephone number The programmable digits are 0 1 2 3 4 5 6 7 8 9 and P for Pause Telephone numbers addresses 008 SMS Service Center To this number the panel sends the SMS data In each country the number is different call ...

Page 33: ...he messages sent by the panel Each number must be programmed as is without access code those numbers are not dialed by the panel they are part of the SMS message Enable the SMS reporting the installer will program 003 set as a factory default 7 3 Events reported by the SMS module To set SMS language English or Hebrew see 200 commands in LED panels only SMS Test reporting Zone event Burglary Zone n...

Page 34: ...y opening a delayed zone the panel begins to dial to the regular telephone numbers In this case the panel sends a siren sound via the telephone If an alarm condition starts the panel was not disarmed the panel will start the normal reporting cycle Report to the Central Station SMS reports and finally alarm reports using siren sound and SVM recorded messages to the regular telephone numbers Central...

Page 35: ...event DTMF control At the end of 1 st Siren SVM cycle the user will be prompted to enter a valid code correct code enables access to the DTMF remote control functions 7 4 Dialer reporting Programming locations Zones to sound Siren via telephone 264 267 default 12345678 Zones to activate SVM1 message 268 271 Zones to activate SVM2 message 272 275 Siren via telephone time seconds 042 default 10s SVM...

Page 36: ...ystems add Pause during dialing hold down key 0 add pause only at add 008 not at address 009 010 Part 2 Central Station CS Settings and Subscribers and Hand Shake HS CS Subsc r 1 code CS Subsc r 2 code Wait to HS time HS Mode CS 1 HS Mode CS 2 Delay Report to CS Must be 4 digits Must be 4 digits 20 seconds Hi Lo Hi Lo 4 seconds 021 025 029 030 031 032 At 030 031 0 1400Hz 1 230 Hz 2 Hi Lo At 032 it...

Page 37: ...seconds 12 111 Remote Zone Bypass via DTMF 0 No 00 063 Entry delay 2 seconds X 4 00 112 Reserved 064 Exit delay seconds X 4 08 113 Enable remote control via PC 0 No 00 065 Time frame for Pulse Count Zone sec 08 114 Remote PC sets the system date 0 no 01 Siren Features 115 Reserved 067 Total siren sound time minutes 04 116 Enable ON output as Elec strike trig 00 068 Siren Test on Arming 0 No 00 117...

Page 38: ...067 248 1 2 3 4 5 6 7 8 249 1 2 3 4 5 6 7 8 A1 output Zone 252 1 2 3 4 5 6 7 8 253 1 2 3 4 5 6 7 8 A2 output Zone 256 257 SLO output Zone not timed 260 261 Siren sound on telephone line 264 1 2 3 4 5 6 7 8 265 1 2 3 4 5 6 7 8 SVM1 message on tel line 268 269 SVM2 message on tel line 272 273 1 2 3 4 5 6 7 8 Chime Zone 276 1 277 1 2 3 4 5 6 7 8 Pulse count Zone 065 280 281 Panic reports to CS Zone 2...

Page 39: ...Zone 067 250 1 2 3 4 5 6 7 8 251 1 2 3 4 5 6 7 8 A1 output Zone 254 1 2 3 4 5 6 7 8 255 1 2 3 4 5 6 7 8 A2 output Zone 258 259 SLO output Zone not timed 262 263 Siren sound on telephone line 266 1 2 3 4 5 6 7 8 267 1 2 3 4 5 6 7 8 SVM1 message on tel line 270 271 SVM2 message on tel line 274 275 1 2 3 4 5 6 7 8 Chime Zone 278 279 1 2 3 4 5 6 7 8 Pulse count Zone 065 282 283 Panic reports to CS Zon...

Page 40: ...ting for new value to be entered Enter a 2 digit value or as required EXAMPLE 1 System in program mode Installer Progr is displayed and the two left most LEDs are blinking 1 Program zones 1 and 4 as Exit Entry Delayed 1 zone 2 Address 104 represents the Exit Entry Delayed 1 zones 3 Press 1 Siren 0 Shunt 4 Delay Delete current value of this address is 1 default program Three LEDs will blink and a L...

Page 41: ... program different formats for each telephone Refer to part 7 of the programming sheet Fill in central station s details Most important parameters are the Receiver Format Handshake frequency and Data Format Opening and Closing Reporting to Central Station By default address 072 Closing Opening reported to central station The report contains the subscriber ID the Closing Opening events and the user...

Page 42: ...wrong it is recommended to set system to the defaults program Warning this function erases all codes and system programming settings 1 Enter program mode 2 Go to address 200 and enter 6 and 9 Display will show Factory Default and system will revert to factory default program and codes Code No 1 is 1 2 3 4 programming code will be 1 9 9 4 Note Erroneous or conflicting programming features are disca...

Page 43: ...ms to operate properly connect the battery Better do not connect any sensors or other devices to the battery terminals Series 4000 is compatible with 12V smoke detectors common collector type or relay output on alarm however adding a manual Reset switch is required Momentary switch achieves smoke detector reset The switch or relay disconnects power to smoke detector following a smoke alarm ...

Page 44: ...esistor RFI and EMI protection Zone line shorting cutting high voltage lightning protection Electro Static Discharge Traps RF Filters Telephone line Lighting protection circuit Auxiliary Power Max AV 4016 13 6 VDC 1 1A Combined Aux Power and Keypad outputs AV 4009 13 6 VDC 0 9A Combined Aux Power and Keypad outputs Battery Charging Current Max 550 mA current limitation Battery Test Indication at k...

Page 45: ...Panic keys were pressed Arm and disarm No siren upon keypad panic but siren test is OK Faulty programming Panic alarm address should have a value greater than 0 zero See address 050 No siren upon alarm at troubled zone Programming Siren fuse Alarm device blown Siren time out addresses should have a value greater than 0 zero Check fuses and Check that sirens operates Dialer dials but no alarm messa...

Page 46: ...es and wait 5 minutes In alarm mode Aux power drops below 10V Aux power overloaded If current consumption of Aux power exceeds max rate add external power supply AV 21 AV 40 No Entry delay Key 4 delete delays was held down Arm and then disarm to cancel this function Programming fails to update features Faulty programming Verify programming features Upon Arming Bypass shunt Orange and Red LEDs ligh...

Page 47: ... is getting hot system doesn t function normally AC power is too high Power supply overloaded or faulty battery shorten Measure the low AC power should not exceed 17V Try to disconnect sensors keypads or other loads that consume high current For additional assistance please contact first your local distributor in case problem not solved contact Av Gad Systems Ltd mention your vendor Our telephone ...

Page 48: ...48 13 Wiring Diagram AV 4009 AV 4009 Wiring Diagram WARNING To prevent electrical shock disengage the System and disconnect the telephone line before servicing this unit ...

Page 49: ... Outputs ON A1 SIR SIR AUSTEL E B E B C C E PHONESTEL LINE SVM IN RX V V TX E B C B E B E E B C PC95 5295 FA2 C6 VA10 U3 Q17 R30 R31 JP2 C22 R10 R25 R7 Q1 C4 C3 C2 C8 R2 R3 JP5 JP4 R78 C16 C39 R79 R9 FA1 FA3 R32 B B Q18 JP3 R81 R83 R86 AC 16 AC R8 JP6 KEY Z9 B1 Fuse Fuse Fuse To V Power PC GSM Here Max 1 10 A OR YE 12 V Version Label Zones 1 to 8 Zone 4 or and 8 EOL options Ground Orange or Yellow...

Page 50: ...6 Wiring Diagram WARNING To prevent electrical shock disengage the System and disconnect the telephone line before servicing this unit Auxiliary Power Output Regulated 13 8V Observe maximum current 1 1A for keypads and 1 1A for Aux power ...

Reviews: