20
Figure 5.4
6. When the refill is complete move the indicator knob
COUNTERCLOCKWISE to the
Regeneration
Complete
position (Figure 5.5). The unit will now
provide softened water.
Figure 5.5
*Note: The times given are only general guidelines.
Adjustment of the times may be necessary for specific
applications and conditions.
Regenerating Iron Filters - Model 942Man
Refer to Regenerating Iron Filters Model 942 in Section
5.2 for information on this type of system application.
All common control settings, control regenerant
settings, and regenerant usage which apply to the
942Man control are the same as those used on the 942
control.
When using the 942Man control however, the time of
each cycle cannot be predicted exactly. Note the
following regeneration cycle parameters:
•
Backwash the filter until the drain water flows clear,
typically 5 - 15 minutes.
•
Regenerant draw continues until the check ball
closes to end draw.
•
Slow
Rinse
should continue until there is NO pink
color to the drain water flow. This is typically four
times that of the regenerant draw time.
•
Fast Rinse time continues until there is no pink
color to the drain water flow, typically 5 - 15
minutes.
•
Refill time is determined by the size of the refill flow
control and the amount of regenerant required for a
particular size system. Refer to Regenerant Use
Table in Section 5.2.
Table 5.1 Suggested Refill Times
Tank
Diameter
Resin
cu.ft.
Refill PN
Refill Flow Rate
gpm (lpm)
@ 60 psig
(414 kPa)
Minimum Salting
(6 lbs/ft
3
)
(96.1 kg/m
3
)
Medium Salting
(10 lbs/ft
3
)
( 160.18 kg/m
3
)
Maximum
Salting (15 lb/ft
3
)
(240.27 kg/m
3
)
14 in (35.5 cm)
3
1040679
0.7 (2.6 lpm)
9 minutes
15 minutes
22 minutes
16 in (40.6 cm)
4
1040680
0.8 (3 lpm)
10 minutes
17 minutes
25 minutes
18 in (45.7 cm)
5
1040681
1.0 (3.8 lpm)
10 minutes
17 minutes
25 minutes
21 in (53.5 cm)
7
1040682
1.4 (5.31 lpm)
10 minutes
17 minutes
25 minutes
24 in (60.9 cm)
10
1040683
2.0 (7.6 lpm)
10 minutes
17 minutes
25 minutes
30 in (76.2 cm)
15
1040684
3.0 (11.4 lpm)
10 minutes
17 minutes
25 minutes
36 in (91.4 cm)
20
1040685
5.0 (18.9 lpm)
8 minutes
14 minutes
20 minutes
Summary of Contents for Magnum Cv 942
Page 1: ...Installation and Service Manual Magnum Cv and Magnum IT Valves...
Page 2: ......
Page 53: ...49 Figure 7 3 Magnum IT Triple Parallel Configuration...
Page 59: ...55 10 0 Performance Data and Charts 10 1 Magnum Injector Data...
Page 60: ...56 Brine draw and Rinse rates on empty tank...
Page 67: ...63 11 4 Triple Parallel Wiring Model 962 Twin or Triple Parallel Wiring Schematic...
Page 68: ...64 11 5 Model 962 Twin Alternating System Main Secondary Wiring Schematic...