background image

 

 

P. 4 

Installation Guide

0

 

3 PIN CONNECTOR – 2 WIRE HARNESS 

Wire  Wire colour 

Function 

Description 

BROWN 

(–) Unlock output 

Programmable 500mA negative output: 1/10-sec., 7/10-sec., 4-
sec. or double 1/4-sec. pulse (

ON

 250 ms, 

OFF

 500 ms, 

ON

 

250 ms) 

No wire 

(+) 12V 

This pin pr12V output for INV-200 module 

GREEN 

(–) Lock output 

Programmable 500mA negative output: 1/10-sec., 7/10-sec. or 
4-sec. pulse  

 
2 PURPLE WIRES 

These wires serve as a starter kill.  Cut the factory starter wire (from the vehicle) in half and connect the two cut 
wires to the 14 AWG purple wires on the module. 

How to Flash the Hood Pin 

THE INSTALLER … 

THE MODULE … 

 

Press and hold the hood pin for 4 seconds. 

 

 

Release the hood pin. 

Parking Lights “ON” 

 

While the parking lights are on, press down the hood pin once more 
and release the hood pin immediately. 

“ON” for 20 seconds 

 

You now have 20 seconds to select one of the sub-menus 

 

 

Programming a Transmitter  

The transmitter does not come pre-programmed and must be programmed after the wiring of the module is 
completed. The system can retain up to 4 different transmitter codes; if a fifth transmitter is programmed, the 
code of the first transmitter in memory will be lost. To erase all transmitters from memory, perform a module 
reset. 

Proceed as follows to program a new transmitter: 

1.

 

Flash the hood pin (see above) - the parking lights will stay on for up to 20 seconds.  

2.

 

Before the lights go out, turn the ignition key to the 

ON (RUN)

 position 

3.

 

When the lights are off, turn the key to the OFF position. 

4.

 

Press and hold the 

 or 

 

button until the parking lights flash 5 times quickly and the siren 

chirps twice. 

5.

 

The transmitter has been stored in memory. 

6.

 

To exit: close the hood. 

To program a transmitter on the second vehicle

 for multi-car operation, you must press the 

 button 

(instead of 

 

or

 

) in step 4 of the transmitter programming procedure.

 

 
Programming Options   

The system is equipped with two custom programming menus that allow the installer to custom-fit the outputs of 
the system according to the requirements of each vehicle. 

 

Proceed as follows to enter custom programming: 

1.

 

Flash the hood pin switch (see above) 

 the parking lights will stay on for up to 20 seconds.  

2.

 

Before the lights go out, press and hold the valet button and then press one of the following 
buttons: 

............................................to access mode 1;

 

............................................to access mode 2;

  

3.

 

The parking lights will flash and the horn will honk (if programmed) once or twice to confirm entry 
into a mode. 

4.

 

Release the valet button 

Summary of Contents for ASL-300

Page 1: ...e 7 Diagnostics Parking Lights Flash Rate 7 Closing Up 8 Included in the Kit Please review the installation guide before beginning the installation especially the wiring diagram and the programming op...

Page 2: ...rammable features are as follows 1 Siren or OEM Horn Output The system can be programmed either to control the OEM horn or to command an external high power siren 2 Siren Horn Chirp Timing This featur...

Page 3: ...ted by Default 5 WHITE RED SIREN OUTPUT This wire will give a positive output when an alarm intrusion has occurred It will also give positive pulses when remotely locking or unlocking the system Siren...

Page 4: ...the first transmitter in memory will be lost To erase all transmitters from memory perform a module reset Proceed as follows to program a new transmitter 1 Flash the hood pin see above the parking li...

Page 5: ...OPTION 1 Constant while button is pressed OPTION 2 Toggle ON Toggle OFF OPTION 3 60 second pulse OPTION 4 1 second pulse with Unlock pulse and Disarm pulse OPTION 5 1 second pulse with Disarm pulse O...

Page 6: ...To adjust the timings for the Horn select MODE 2 FUNCTION 4 OPTION 3 or 4 The siren horn chirp duration can be configured by following these steps 1 Flash the hood pin switch see on page 4 the parking...

Page 7: ...of a 2nd zone disable requires an external relay not included Multi car Operation This allows the user to control two systems with one transmitter Both vehicles must be equipped with identical module...

Page 8: ...such as the Parking Brakes or Steering Column Shafts Mount all switches in good and accessible locations where they do not risk getting kicked or hit accidentally Most comebacks are the result of mis...