16
9 Hysteresefunktion P1 = P2
AU011-AU013
Start programming mode of the device.
(7.1)
►
Objekt auf Position P1.
►
Teacheingang ca. 1 s verbinden.
> LED blinkt (2,5 Hz).
►
Objekt auf Position P2.
►
Teacheingang ca. 1 s verbinden.
> LED blinkt (4 Hz).
> If programming is not completed
successfully, the LED does not
flash and the instrument returns to
the previous setting.
AU014-AU018
Start programming mode of the device.
(7.2)
►
Objekt auf Position P1.
►
Taste 1 x 1 s drücken
> LED blinkt (2,5 Hz).
►
Objekt auf Position P2.
►
Taste 1 x 1 s drücken
> LED blinkt (4 Hz).
> If programming is not completed
successfully, the LED does not
flash and the instrument returns to
the previous setting.
10 Inverting the output response
► Connect teach input > 6 s → 7 Wire programming. (AU011-AU013)
►
Press button > 6 s. (AU014-AU018)
> LED flashes (> 10 Hz).
> Output functions are inverted (NO becomes NC or vice versa).
B
P1/P2
Y
X
Y
X
1
2
Output response of the switching
/ analogue output
X: Distance
Y: Output response
①:
OUT1 (switching output)
②:
OUT2 (switching output / analogue output)
B: Blind zone
P1: Setting point 1
P2: Setting point 2
X: Distance
Y: Comportamento dell‘uscita
②:
OUT2 (analogue output)
B: Blind zone
P1: Setting point 1
P2: Setting point 2
Output response of
analogue output
B
P1/P2
Y
X
Y
X
1
2