background image

6

·

Alerts receiving

If the remote control unit has got inputs to obtain information about the heater 
operation, they can be connected to the RCP’s outputs Alert_1 and Alert_2. The 
outputs have negative polarity. Therefore if remote control unit not fit it, it needs to 
apply a matching circuit (with relay ex.).
Events given on the outputs Alert_1 and Alert_2 are adjusted by the settings 7.3 and 
7.4 accordingly. Also the output line Timer_out can be used to send notification 
how much time the heater operates.

·

Status output line application

1.

Indication of the heater operation by the hazard warning flashers (in addition 
to the direction indicators in rear-view mirrors). 

The module can indicate of the heater operation by hazard flashers. Connect the
module’s output X2.2 to the grey-red wire (pin 3 of the connector) of the hazard 
warning switch, and choose the settings 7.5.3 (the settings 6.2-6.7 also need to 
be adjusted) for this purpose.

3)

Installation procedure for permanent connection

·

General recommendations

The required tools: Torx screwdriver, wire cutter, wire stripper.

·

Remove the panel around the service connector on the left side of the 
dashboard

·

Find place inside the dashboard to install the module (mounted on double-
sided tape)

·

Connect the module to car’s wiring according to the scheme at the fig.1. 
Connect the module to the receiver unit of remote control, according to the 
schemes at the figures 3-9. Make task specific connections, if necessary.

The module is powered and connected to the CAN-bus wires near the service 
connector using quick splice connectors (supplied). 

The module’s power (pin X1.9) connects to the orange wire of service connector
(pin 16), the module’s signal ground (pin X1.8) – to the black-white wire of service 
connector (pin 4). 
The signal «CAN-L» (pin X2.9) connects to the violet-orange wire (pin 11), the 
signal «CAN-H» (pin X2.10) – to the grey-orange wire (pin 3). Twist brown and 
brown-white wires of the connector X2 to the pair before connections. It is not
recommended to lengthen these wires.

Summary of Contents for RCP-V2

Page 1: ...Autoplugin RCP V2 Installation Manual Rev A...

Page 2: ...Blue Additional devices control Brown white Green Green yellow Autoplugin RCP V2 Red white Feedback to remote control to scheme of turning off Blue Grey Brown Outer indicator to scheme of turning on f...

Page 3: ...r the heater remote start by using Volvo key turn on perimeter lighting then press Lock button twice Find place under the dashboard for the module and fix it with adhesive tape Shorten length of the c...

Page 4: ...ive polarity Green Blue X1 3 4 to RC RCP Ground X1 3 4 Battery to RC Green Blue RCP Figure 2 Figure 3 o The fig 4 presents the scheme to turn the heater off by the impulse of positive polarity The fig...

Page 5: ...Easy Start Webasto Telestart If direct connection of remote control s output line to the input RC_in is not functional the scheme at the fig 7 can be applied 85 86 30 87 to X1 7 of RCP Can to RC Rela...

Page 6: ...o be adjusted for this purpose 3 Installation procedure for permanent connection General recommendations The required tools Torx screwdriver wire cutter wire stripper Remove the panel around the servi...

Page 7: ...possible solutions Table 1 Error Code Error Description Possible Reasons of Error Appearance Solutions 2 No answer from the heater followed the start command The heater is not activated in the CIP Con...

Page 8: ...20 minutes Make diagnostics of the heater if the error appears again 8 CAN bus error The lines X2 9 X2 10 connected incorrectly Check the lines connection 9 Settings error Settings have been incorrect...