background image

LM 706 A/C Service Station

10

B-6: When finished, the equipment stops automatically. Then restore the line.

Note: for safety reasons, some fresh refrigerant tank has no liquid port so that it don’t
support the use of refrigerant upside down (that is, when upside down, no refrigerant
flows out of the cylinder). At this time, the cylinder should be placed upright and
supplemented with the recovery function.

3.11.2.4

Exchange dry filter

A

The dry filter must be exchange when it reaches the life time. There will give a message.

B

If not exchange the dry-filter timely, it will not be able to run the recovery and supplying

functions.

C

Please read the ID of the dry-filter at the label. Which is the value followed by letter SN.

D

Please attention the mounting direction of the dry-filter.

3.11.2.5

Drain used oil

Normally, the equipment will automatically drain the used oil after flushing and/or recovery

function. In case of power failure and artificial termination of operation, this function can be

used to discharge the used oil separated from the equipment.

Press ENTER key once, it will drain oil once. Press and hold ENTER key to drain used oil

continuously.

Note: in order to avoid bottle explosion due to high internal pressure, it is strongly

recommended to use point by point method to drain oil!

3.11.2.6

Self-purify

For a period of time, there will be a small amount of frozen oil residue in the glass window,

internal pipeline and other parts. At this time, it can be treated by the self-purify function of the

equipment. The operation steps are as follows:

A

Recovery the refrigerant in the pipeline.

Summary of Contents for LM 706

Page 1: ...LM 706 A C Service Station LM 706 A C Service Station...

Page 2: ...ts such as cooling fans alternators and heating components etc to avoid harm Wear protective clothing gloves and goggles As automotive air conditioning pipe flushing the operator must be fully familia...

Page 3: ...3 6 Vacuum 5 3 7 Fill new oil 5 3 8 Recharging 6 3 9 Auto Mode 7 3 10 Database 7 3 11 Auxiliary functions 8 3 11 1 Usage of the Auxiliary Port 8 3 11 2 System functions 8 3 11 2 1 Parameter setting 8...

Page 4: ...with the gas or the liquid C Touch button improved control performance long service life D Designed with large size LCD E Database F USB update port program and database can be updated G Equipped with...

Page 5: ...Vacuum C Fill new oil D Recharging E Auto Mode 2 2 Subsidiary functions A Database B Parameter setting C Calibration professional D Supply main tank E Maintenance procedures dry filter exchange vacuu...

Page 6: ...Open the back door take out all the fillers on both sides of the cylinder and under the scale pan so that the scale pan is suspended B Set language select and press OK HP gauge Operation panel LP gau...

Page 7: ...gerants at least 2kg F Please read this user manual carefully before operating 3 3 Preparations before Operation A Connect the red blue couplers to the HP LP ports of automobile air conditioner respec...

Page 8: ...or with the front and rear wind C Operations Note after the operation of the equipment there is no need for personnel to take care of it until it is finished by itself D If it displays code as W durin...

Page 9: ...the equipment stops automatically Note in the process of new oil filling do not take the oil bottle and shake the equipment otherwise it will lead to inaccurate filling 3 8 Recharging Through this fu...

Page 10: ...plete the recharging process Later you should supply new refrigerant into the tank 3 9 Auto Mode A Under this mode all of the functions can be run full automatically after setting the parameters B Bef...

Page 11: ...back the cap to the auxiliary port Tip when using the external tank to fill the refrigerant it may be necessary to start the car and turn on the air conditioner in some cases It is forbidden to conne...

Page 12: ...igerant of the equipment is less than 2kg it need to be supplemented If the refrigerant is less than 1kg the filling function will not be performed B Operations B 1 Select Supply main tank function B...

Page 13: ...ollowed by letter SN D Please attention the mounting direction of the dry filter 3 11 2 5 Drain used oil Normally the equipment will automatically drain the used oil after flushing and or recovery fun...

Page 14: ...ry System inquiry you can query the equipment usage Servicer info inquire about the phone number of the service provider Equipment infor query equipment serial number software and hardware version and...

Page 15: ...l clean and ventilated place h The maintenance items indicated by the equipment should be done in time i When the equipment is not in use for a long time or when it is loaded and transferred to anothe...