13. TECHNICAL DESCRIPTION AND SPECIFICATIONS
USA-Federal Communications Commission (FCC)
The following is communication regulation information on the Pulsante SPG microstimulator system
comprises of Neurostimulator NS-100 and Remote Controller RC-300.
FCC ID of the system: 2APE8-RC300
Labeling Note:
FCC ID information can be retrieved by pressing and holding the Remote Controller
RC-300 power button for 10seconds.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This product does not contain any user serviceable components. Any unauthorized product changes
or modifications will invalidate warranty and all applicable regulatory certifications and approvals,
including authority to operate this device.
FCC Part 15 Digital Emissions Compliance We, Autonomic Technologies, Inc, declare under our sole
responsibility that this product complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
WARNING: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates and
radiates radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from the one the receiver is
connected to.
Consult the dealer or an experienced radio/TV technician for help. The user may find the following
booklet prepared by the Federal Communications Commission helpful: The Interference Handbook.
This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402. Stock
No.004-000-00345-4.
Electromagnetic Compatibility
The use of cables other than those specified or sold by Autonomic Technologies may result in
increased emissions or decreased electrical immunity of the system. The RF transmitter within the
remote controller operates at 126 kHz +/- 3kHz, with Frequency Shift Keying (FSK), and the effective
radiated power of less than 5mW. NOTE: The device remains safe under its typical electromagnetic
interference environment. The Pulsante® SPG Microstimulator System complies with the international
standard IEC 60601-1-2, Edition 4.0 2014-02 for Electromagnetic Compatibility (EMC). Use of this
equipment should follow the Electromagnetic Compatibility (EMC) guidance below.