Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

0.0 - 500.0 VACᜠ

0.0 to 500.0

50)0

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

4.062 MΩ

0 - 500 VACᜠ

0 to 500 

500

0.0 - 200.0 VACᜠ

0.0 to 200.0

20)0

0 - 200 VACᜠ

0 to 200

200

0.0 - 110.0 VACᜠ

0.0 to 110.0

11)0

0 - 110 VACᜠ

0 to 110

110

0.00 - 50.00 VACᜠ

0.00 to 50.00

5)00

162 kΩ

0.0 - 50.0 VACᜠ

0.0 to 50.0

5)0

0.00 - 20.00 VACᜠ

0.00 to 20.00

2)00

0.0 - 20.0 VACᜠ

0.0 to 20.0

2)0

0.000 - 5.000 VACᜠ

0.000 to 5.000

%000

0.00 - 5.00 VACᜠ

0.00 to 5.00

%00

0.000 - 2.000 VACᜠ

0.000 to 2.000

@000

0.00 - 2.00 VACᜠ

0.00 to 2.00

@00

0.0 - 500.0 mVACᜠ

0.0 to 500.0 

50)0

4 kΩ

0 - 500 mVACᜠ

0 to 500

500

0.0 - 200.0 mVACᜠ

0.0 to 200.0

20)0

0 - 200 mVACᜠ

0 to 200

200

0.00 - 50.00 mVACᜠ

0.00 to 50.00

5)00

0.0 - 50.0 mVACᜠ

0.0 to 50.0

5)0

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

Input Range and Display Range

When the max. input value is over the 100 %, it may result in input terminal damage.

  

■ DC / AC voltage model (input type: DC)

Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

0.0 - 500.0 VDCᜡ

0.0 to 500.0

50)0

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

4.062 MΩ

0 - 500 VDCᜡ

0 to 500 

500

0.0 - 200.0 VDCᜡ

0.0 to 200.0

20)0

0 - 200 VDCᜡ

0 to 200

200

0.00 - 50.00 VDCᜡ

0.00 to 50.00

5)00

0.0 - 50.0 VDCᜡ

0.0 to 50.0

5)0

0.00 - 20.00 VDCᜡ

0.00 to 20.00

2)00

162 kΩ

0.0 - 20.0 VDCᜡ

0.0 to 20.0

2)0

0.000 - 5.000 VDCᜡ

0.000 to 5.000

%000

0.00 - 5.00 VDCᜡ

0.00 to 5.00

%00

1.000 - 5.000 VDCᜡ

1.000 to 5.000

1-5A

1.00 - 5.00 VDCᜡ

1.00 to 5.00

1-5B

0.000 - 2.000 VDCᜡ

0.000 to 2.000

@000

0.00 - 2.00 VDCᜡ

0.00 to 2.00

@00

0.0 - 500.0 mVDCᜡ

0.0 to 500.0

50)0

4 kΩ

0 - 500 mVDCᜡ

0 to 500

500

0.0 - 200.0 mVDCᜡ

0.0 to 200.0

20)0

0 - 200 mVDCᜡ

0 to 200

200

0.00 - 50.00 mVDCᜡ

0.00 to 50.00

5)00

0.0 - 50.0 mVDCᜡ

0.0 to 50.0

5)0

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

  

■ DC / AC voltage model (input type: AC)

Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

-500.0 - 500.0 VDCᜡ

-500.0 to 500.0

-50)0

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

4.062 MΩ

-500 - 500 VDCᜡ

-500 to 500

-500

-200.0 - 200.0 VDCᜡ

-200.0 to 200.0

-20)0

-200 - 200 VDCᜡ

-200 to 200

-200

-50.00 - 50.00 VDCᜡ

-50.00 to 50.00

-5)00

162 kΩ

-50.0 - 50.0 VDCᜡ

-50.0 to 50.0

-5)0

-20.00 - 20.00 VDCᜡ

 -20.00 to 20.00

-2)00

-20.0 - 20.0 VDCᜡ

-20.0 to 20.0

-2)0

-5.000 - 5.000 VDCᜡ

-5.000 to 5.000

-%000

-5.00 - 5.00 VDCᜡ

-5.00 to 5.00

-%00

-2.000 - 2.000 VDCᜡ

-2.000 to 2.000

-@000

-2.00 - 2.00 VDCᜡ

-2.00 to 2.00

-@00

-500.0 - 500.0 mVDCᜡ

-500.0 to 500.0 

-50)0

4 kΩ

-500 - 500 mVDCᜡ

-500 to 500

-500

-200.0 - 200.0 mVDCᜡ

-200.0 to 200.0

-20)0

-200 - 200 mVDCᜡ

-200 to 200

-200

-50.00 - 50.00 mVDCᜡ

-50.00 to 50.00

-5)00

-50.0 - 50.0 mVDCᜡ

-50.0 to 50.0

-5)0

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

  

■ DC / AC voltage model (input type: -DC)

  

■ DC / AC current model (input type: AC)

  

■ DC / AC current model (input type: DC)

  

■ DC / AC current model (input type: -DC)

Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

0.000 - 5.000 A

0.000 to 5.000

%000

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

0.02 Ω

0.00 - 5.00 A

0.00 to 5.00

%00

0.000 - 2.000 A

0.000 to 2.000

@000

0.00 - 2.00 A

0.00 to 2.00

@00

0.0 - 500.0 mA

0.0 to 500.0

50)0

0.87 Ω

0 - 500 mA

0 to 500

500

0.0 - 200.0 mA

0.0 to 200.0

20)0

0 - 200 mA

0 to 200

200

0.00 - 50.00 mA

0.00 to 50.00

5)00

0.0 - 50.0 mA

0.0 to 50.0

5)0

0.00 - 20.00 mA

0.00 to 20.00

2)00

21.87 Ω

0.0 - 20.0 mA

0.0 to 20.0

2)0

4.00 - 20.00 mA

4.00 to 20.00

4A20

4.0 - 20.0 mA

4.0 to 20.0

4B20

0.000 - 5.000 mA

0.000 to 5.000

%000

0.00 - 5.00 mA

0.00 to 5.00

%00

0.000 - 2.000 mA

0.000 to 2.000

@000

0.00 - 2.00 mA

0.00 to 2.00

@00

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

-5.000 - 5.000 A

-5.000 to 5.000

-%000

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

0.02 Ω

-5.00 - 5.00 A

-5.00 to 5.00

-%00

-2.000 - 2.000 A

-2.000 to 2.000

-@000

-2.00 - 2.00 A

-2.00 to 2.00

-@00

-500.0 - 500.0 mA

-500.0 to 500.0

-50)0

0.87 Ω

-500 - 500 mA

-500 to 500

-500

-200.0 - 200.0 mA

-200.0 to 200.0

-20)0

-200 - 200 mA

-200 to 200

-200

-50.00 - 50.00 mA

-50.00 to 50.00

-5)00

-50.0 - 50.0 mA

-50.0 to 50.0

-5)0

-20.00 - 20.00 mA

-20.00 to 20.00

-2)00

21.87 Ω

-20.0 - 20.0 mA

-20.0 to 20.0

-2)0

-5.000 - 5.000 mA

-5.000 to 5.000

-%000

-5.00 - 5.00 mA

-5.00 to 5.00

-%00

-2.000 - 2.000 mA

-2.000 to 2.000

-@000

-2.00 - 2.00 mA

-2.00 to 2.00

-@00

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.

Input range

Display range

Input 

impedance

Diaplay method: STND (fixed) Diaplay method

: SCAL 

 01)

0.000 - 5.000 A

0.000 to 5.000

%000

Decimals

Display range

0

-9999 to 9999

)0

-999.9 to 999.9

)00

-99.99 to 99.99

)000

-9.999 to 9.999

0.02 Ω

0.00 - 5.00 A

0.00 to 5.00

%00

0.000 - 2.000 A

0.000 to 2.000

@000

0.00 - 2.00 A

0.00 to 2.00

@00

0.0 - 500.0 mA

0.0 to 500.0

50)0

0.87 Ω

0 - 500 mA

0 to 500

500

0.0 - 200.0 mA

0.0 to 200.0

20)0

0 - 200 mA

0 to 200

200

0.00 - 50.00 mA

0.00 to 50.00

5)00

0.0 - 50.0 mA

0.0 to 50.0

5)0

0.00 - 20.00 mA

0.00 to 20.00

2)00

21.87 Ω

0.0 - 20.0 mA

0.0 to 20.0

2)0

0.000 - 5.000 mA

0.000 to 5.000

%000

0.00 - 5.00 mA

0.00 to 5.00

%00

0.000 - 2.000 mA

0.000 to 2.000

@000

0.00 - 2.00 mA

0.00 to 2.00

@00

 01)  Connect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input 

range to measure.  

When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.