Autonics MX4W Series Product Manual Download Page 2

-|Transparent Guide|-

Product Components

• Product 
• Bracket × 2

• Instruction manual 
• Terminal cover × 1

Cautions during Wiring

• 

Unit: mm, Use terminals of size specified 

below.

• Input and output are insulated from the 

power.

≥3.0

≤6.0

ADC input 

circuit and 

display part

Option output 

and 

hold / zero

Power

1

3

2

4

5

7

6

8 9

10

Dimensions

• Unit: mm, For the detailed drawings, follow the Autonics website.

91.5

48

44.4

96

4 20

  

Bracket

  

■ Panel cut-out

22

36

3

4.9

≥ 116

≥ 52

92

+0.8

  0

45

+0.6

  0

  

Terminal cover

15.5

15.9

93.7

Ordering Information

This is only for reference, the actual product does not support all combinations.

For selecting the specified model, follow the Autonics webstie.  

MX 4 W

-

-

F

❶ Input type

V: DC / AC voltage
A: DC / AC current

❷ Preset output

N: Indicator
1: NPN open collector 
2: PNP open collector 

Connections

  

■ Input

• For using DC power, connect wires regardless of polarity.

• Indicator model does not have the hold / zero terminal.

HOLD / ZERO

SOURCE

24 - 240 VACᜠ/ VDCᜡ

COM

1

2

3

4

5

6

7

8

9

10

MX4W-V-

F□

MX4W-A-

F□

DC

± 500 mVDCᜡ / ± 200 mVDCᜡ / 

± 50 mVDCᜡ

± 20 mA / 4 - 20 mA / ± 5 mA / ± 2 mA

AC

0 - 500 mVACᜠ / 0 - 200 mVACᜠ / 

0 - 50 mVACᜠ

0 - 20 mA / 0 - 5 mA / 0 - 2 mA

DC

± 20 VDCᜡ / ± 5 VDCᜡ / 1 - 5 VDCᜡ / 

± 2 VDCᜡ

± 500 mA / ± 200 mA / ± 50 mA

AC

0 - 20 VACᜠ / 0 - 5 VACᜠ / 0 - 2 VACᜠ

0 - 500 mA / 0 - 200 mA / 0 - 50 mA

DC

± 500 VDCᜡ / ± 200 VDCᜡ / ± 50 VDCᜡ

± 5 A / ± 2 A

AC

0 - 500 VACᜠ / 0 - 200 VACᜠ / 

0 - 110 VACᜠ / 0 - 50 VACᜠ

0 - 5 A / 0 - 2 A

  

■ Output

• 

1: NPN open collector

COM

OUT2

OUT1

1

2

3

4

HOLD/

ZERO

• 

2: PNP open collector

COM

OUT2

OUT1

1

2

3

4

HOLD/

ZERO

Specifications

Model

MX4W-V-

F□

MX4W-A-

F□

Input type

DC / AC voltage

DC / AC current

Max.

 allowable 

input 

Dependent on the input type

 +DC  input

≈ -10 to 110 % F.S. for each measured input range

-DC input

≈ -110 to 110 % F.S. for each measured input range

AC input

≈ 110 % F.S. for each measured input range

Display method

12-segment LCD

 01)

 

measurement value display part

: white, character height: 19 mm

other display parts

: red, green, yellow (indicator: white)

Display accuracy

Dependent on the ambient temperature

23 ± 5 ℃ (DC input)

± 0.1 % F.S. rdg ± 2-digit

± 0.1 % F.S. rdg ± 2-digit 

 02)

23 ± 5 ℃ (AC input) 

± 0.3 % F.S. rdg ± 3-digit

± 0.3 % F.S. rdg ± 3-digit 

0 to 50 ℃

± 0.5 % F.S. rdg ± 3-digit

± 0.5 % F.S. rdg ± 3-digit 

 03)

Display cycle

0.2 to 5.0 sec (select per 0.1 sec)

Display scale

-9999 to 9999 (4-digit) 

A / D 

conversion method

ΣΔ (Sigma Delta) analog-to-digital converter

Sampling cycle

(DC input)

50 ms

Sampling cycle

 

(AC input)

16.6 ms

Resolution

1 / 20,000

P

reset output

 NPN / PNP open collector output model

Load voltage

≤ 30 VDCᜡ

Load current

≤ 100 mA

Residual voltage

NPN open collector output: ≤ 1 VDCᜡ / 

PNP open collector output: ≤ 2 VDCᜡ 

Unit weight (packaged)

≈ 77 g (≈ 100 g)

Approval

ᜢ ᜧ

 01)  When using the unit at low temperature (below 0 ℃), display cycle is slow due to charateristics of LCD. Control 

output operates normally.

 02) 5 A 

terminal

: ± 0.3 % F.S. rdg ± 3-digit

 03) 5 A 

terminal

: ± 1 % F.S. rdg ± 3-digit 

Power supply

24 - 240 VDCᜡ ± 10 %, 24 - 240 VACᜠ ± 10 %  50 / 60 Hz

Power consumption 

DC: ≤ 3 W, AC: ≤ 5 VA

Insulation resistance

≥ 100 MΩ (500 VDCᜡ megger)

Dielectric strength 

B

etween all terminals and case: 3,000 VACᜠ 50 / 60 Hz for 1 min

Noise immunity 

± 2 kV square wave noise (pulse width: 1 

㎲) by the noise simulator

Vibration

0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 

minute) in each X, Y, Z direction for 2 hours

Vibration 

(malfunction)

0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute) 

in each X, Y, Z direction for 10 min

Shock 

300 m/s

(≈ 30 G) in each X, Y, Z direction for 3 times

Shock (malfunction)

100 m/s

(≈ 10 G) in each X, Y, Z direction for 3 times

Ambient temperature

-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)

Ambient humidity

35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)

Insulation type

Symbol: 

double or reinforced insulation

 (dielectric strength 

between the measurement input part and the power part:

 

1 kV) 

Reviews: