-|Transparent Guide|-
Software
Download the installation file and the manuals from the Autonics website.
■
DAQMaster
It is the comprehensive device management program for Autonics' products, providing
parameter setting, monitoring and data management.
Manual
For proper use of the product, refer to the manuals and be sure to follow the safety
considerations in the manuals.
Download the manuals from the Autonics website.
Product Components
• Product
• Bracket × 2
• Instruction manual
• Unit sticker × 1
Dimensions
•
Unit: mm, For the detailed drawings, follow the Autonics website.
■
Indicator
/
Relay
preset output model
96
6
100
45
48
■ NPN / PNP open collector preset output model
6
89.5
14.9
45
96
48
■
Bracket
■ Panel cut-out
14.5
73
4.4
12
10
≥ 116
92
+0.8
0
45
+0.6 0
≥ 52
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MT 4 W
-
❶
-
❷ ❸
❶ Input type
DV: DC voltage
01)
DA: DC current
AV: AC voltage
02)
AA: AC current
02)
❷ Power supply
1: 12 - 24 VDCᜡ ± 10 %
4: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz
❸ Preset Sub output
P
reset output
Sub
output
N
None (indicator)
0
Relay
Transmission (DC 4 - 20 mA)
1
Relay
-
2
NPN open collector
BCD Dynamic
3
PNP open collector
BCD Dynamic
4
NPN open collector
Transmission (DC 4 - 20 mA)
5
PNP open collector
Transmission (DC 4 - 20 mA)
6
NPN open collector
Low speed
serial
7
PNP open collector
Low speed
serial
8
NPN open collector
RS485 Communication
9
PNP open collector
RS485 Communication
01) To measure the current over DC 5 A, please select DV type because the shunt should be used.
02) In case of selecting frequency display, no output will be provided even if it is output support model.
Cautions during Wiring
Use the Copper-conductor wire with the temperature class 60 ℃.
•
Unit: mm, Use terminals of size
specified below.
• Contact the manufacture for the socket and
cable.
≥3.5
≤7.0
Model
Hirose connector
HIF3BA-20PA-2.54DS
Hirose connector socket HIF3BA-20D-2.54R
2
20
19
1
Connections
■ Input
•
DC voltage
HOLD / ZERO
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
COM
250 mVDCᜡ / 50 mVDCᜡ
5 VDCᜡ / 1 VDCᜡ
50 VDCᜡ / 10 VDCᜡ
500 VDCᜡ / 100 VDCᜡ
1 2 3 4 5 6 7
8 9
• DC current
HOLD / ZERO
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
COM
5 mA / 2 mA
50 mA / 4 - 20 mA
500 mA / 200 mA
5 A / 2 A
1 2 3 4 5 6 7
8 9
•
AC voltage
HOLD / ZERO
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
COM
2 VACᜠ / 1 VACᜠ
20 VACᜠ / 10 VACᜠ
110 VACᜠ / 50 VACᜠ
500 VACᜠ / 250 VACᜠ
1 2 3 4 5 6 7
8 9
• AC current
HOLD / ZERO
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
COM
100 mA / 50 mA
500 mA / 250 mA
1 A
5 A / 2.5 A
1 2 3 4 5 6 7
8 9
■ Output
• 0: Relay
+
Transmission
(DC 4 - 20 mA)
DC 4 - 20 mA
Load 600 Ω Max.
Main OUT
Contact OUT: 250 VACᜠ 3A 1a
resistive load
GO
COM
LO
HI
10 11 12 13 14 15
mA
• 1: Relay
GO
LO
HI
Main OUT
Contact OUT: 250 VACᜠ 3A 1a
resistive load
10 11 12 13 14 15
•
2: NPN open col BCD Dynamic
GO
COM1
LO
HI
0V
B
+24 VDCᜡ
30mA Max.
A
D
C
D1
D0
D3
D2
DOTCOM2
POL
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
BCD OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
•
3: PNP open col BCD Dynamic
GO
COM1
LO
HI
0V
B
+24 VDCᜡ
30mA Max.
A
D
C
D1
D0
D3
D2
DOTCOM2
POL
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
BCD OUT
(PNP open collector)
12 - 24 VDCᜡ Max. 50 mA
•
4: NPN open col
Transmission
(DC 4 - 20 mA)
GO
COM1
LO
HI
0V
+24 VDCᜡ
30mA Max.
DC 4 - 20 mA
Load 600 Ω Max.
-
+
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
•
5: PNP open col
Transmission
(DC 4 - 20 mA)
GO
COM1
LO
HI
0V
+24 VDCᜡ
30mA Max.
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
DC 4 - 20 mA
Load 600 Ω Max.
-
+
•
6: NPN open col Low speed
serial
GO
COM1
LO
HI
0V
+24 VDCᜡ
30mA Max.
Serial OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
LATCH
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
CLOCK
POL
COM2 DATA
•
7: PNP open col Low speed
serial
GO
COM1
LO
HI
0V
+24 VDCᜡ
30mA Max.
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
CLOCK
POL
COM2 DATA
Serial OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
LATCH
•
8: NPN open col RS485 Comm.
GO
COM1
LO
HI
0V
+24 VDCᜡ
30mA Max.
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
SG
B (-)
RS485
A (+) SG
•
9: PNP open col RS485 Comm.
GO
COM1
LO
HI
0V
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
1
4
3
6
5
8
7
10
9
12
11
14
13
16
15
18
17
20
19
+24 VDCᜡ
30mA Max.
SG
B (-)
RS485
A (+) SG