Autonics GP-S070 Instruction Download Page 10

R-6

General Features

Series 

Connectable 

device

Connection type

GP-S057

GP/LP-

S044

GP/LP-

S070

LS Master-K

MK-10S1

CPU direct connection loader ○

MK-80S

CPU direct connection loader ○

MK-120S

CPU direct connection loader ○

MK-200S

CPU direct connection loader ○

MK-300S

CPU direct connection loader ○

MK-1000S 

CPU direct connection loader ○

LS Glofa

GM4 

CPU direct connection loader ○

GM6

CPU direct connection loader ○

GM7U

CPU direct connection loader ○

LS CNET

(Cnet integrated CPU)

MK-80S

Cnet

MK-120S

Cnet

MK-200S

Cnet

LS CNET

(For Cnet unit)

MK-80S

Cnet

MK-120S

Cnet

MK-200S

Cnet

MK-300S

Cnet

MK-1000S

Cnet

LS XGT(For Cnet unit)

XGK- PUS

Cnet

LS XGB

(Cnet integrated CPU)

XBM 

Cnet

XBC 

Cnet

LS XGB

(For Cnet unit)

XBM 

Cnet

XBC 

Cnet

OEMAX

(SAMSUNG)

N70 

Cnet

N70Plus 

Cnet

OEMAX FARA

NX7 

CPU direct connection loader ○

NX70 

CPU direct connection loader ○

MITSUBISHI FX 

FX1S 

CPU direct connection loader ○

FX1N 

CPU direct connection loader ○

FX2N 

CPU direct connection loader ○

FX2NC 

CPU direct connection loader ○

FX3U 

CPU direct connection loader ○

MITSUBISHI Q

(For Cnet unit)

Q00J 

Cnet

Q00 

Cnet

Q01 

Cnet

Q02 

Cnet

Q02H 

Cnet

Q06H 

Cnet

Q12H 

Cnet

Q25H 

Cnet

NAIS FP 

FP0-C10 

CPU direct connection loader ○

FP0-C14 

CPU direct connection loader ○

FP0-C16

CPU direct connection loader ○

FP0-C32 

CPU direct connection loader ○

FPG- C24R2 

CPU direct connection loader ○

FPG- C32T 

CPU direct connection loader ○

FPG- C32T2 

CPU direct connection loader ○

FP0R-C10 

CPU direct connection loader ○

FP0R-C14 

CPU direct connection loader ○

FP0R-C1 

CPU direct connection loader ○

FP0R-C32 

CPU direct connection loader ○

FP0R-T32 

CPU direct connection loader ○

FP0R-F32

CPU direct connection loader ○

SIEMENS

SIMATIC

S7-200 

CPU221

CPU direct connection loader ○

CPU222

CPU direct connection loader ○

CPU224

CPU direct connection loader ○

CPU224XP

CPU direct connection loader ○

CPU224XPsi 

CPU direct connection loader ○

CPU226

CPU direct connection loader ○

 Connectable device with GP/LP  

Summary of Contents for GP-S070

Page 1: ...ue Color with 16 777 216 colors Analog touch method Free tag arrangement than matrix touch method Data logger function Supports data gathering and backup of controller Supports variable image library Enables to monitor multi station and multi channel at the same time Supports several interface Supports USB Host Device to high speed download and manage files Easy to connect various external devices...

Page 2: ... for front panel Accessory Fixing bracket 4EA Battery included Approval Unit weight Approx 520g Figure display Line rectangle circle text bitmap Tags Numeral display Displays the designated device as numerical value decimal hexadecimal octal binary real number ASCII display Displays the designated device value as ASCII character Time display Displays current time or date Alarm history Registers al...

Page 3: ...een RS422 or RS232C A USB Device USB Host Ethernet RS422 or RS232C B M4 BOLT Max 4 R3 15 Min 240 Panel thickness Max 4mm 6 5 28 5 134 125 146 Min 175 Mounting slot for bracket Panel cut out Fixing bracket unit mm Dimensions 186 1 1 0 126 1 0 0 Part description Ethernet Port For connecting LAN cable and hub use direct cable and for connecting PC directly use cross cable USB Device It is used to upl...

Page 4: ...t fixing brackets in 4 slots 2 slots is in upper side 2 slots is in lower side Sold separately Transmission cables connectable into external devices such as PLC are sold separately refer to the R 32 page for GP LP communication cable 3 Tighten fixing bracket with M4 Screw driver and tightening torque is 0 3 to 0 5N m ...

Page 5: ... including PC PLC serial printer barcode reader and dedicated connectors can be connected into both RS232C and RS422 ports Device must be set for the port in system setting for LP S044 LP S070 For details refer to GP user manual Use the dedicated communication cable for the each connected device Refer to the GP LP communication cable of R 32 page For the method of wiring external devices of PLC re...

Page 6: ...ated environment of operation and control It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices Setting and change of production process It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices Convenient setting ...

Page 7: ... SmartStudio programming manual Refer to the manual for details on website www autonics com resources Basic operation flow LP Logic Panel Logic panel is created for integrated panel in most demanding industrial environments that have been consisted of HMI PLC and I O The LP through integration realizes cost down wire reduction space saving and enhanced user friendliness The logic panel perfectly s...

Page 8: ...es Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices System configurations Stand alone LP Series Stand alone system in LP series controls a variety of I O without adding other...

Page 9: ...0Ω please use the wire of min 1 25mm dimension Please check the pin number and connect to GP LP communication port Please tighten bolt on terminal block with specified tightening torque When liquid crystal from the broken LCD is smeared on your skin wash it for 15 minutes If it is gotten in your eye wash it for 15 minutes and contact a medical specialist for more information Do not inflow dust or ...

Page 10: ...PU direct connection loader FX1N CPU direct connection loader FX2N CPU direct connection loader FX2NC CPU direct connection loader FX3U CPU direct connection loader MITSUBISHI Q For Cnet unit Q00J Cnet Q00 Cnet Q01 Cnet Q02 Cnet Q02H Cnet Q06H Cnet Q12H Cnet Q25H Cnet NAIS FP FP0 C10 CPU direct connection loader FP0 C14 CPU direct connection loader FP0 C16 CPU direct connection loader FP0 C32 CPU ...

Page 11: ...Connection type GP S057 GP LP S044 GP LP S070 SIEMENS SIMATIC S7 300 CPU312 CPU direct connection loader CPU312C CPU direct connection loader CPU313C CPU direct connection loader CPU313C 2 CPU direct connection loader CPU314 CPU direct connection loader CPU314C 2 CPU direct connection loader CPU315 2 CPU direct connection loader CPU317 2 CPU direct connection loader CPU319 3 CPU direct connection ...

Reviews: