Autonics GP-S070 Instruction Download Page 1

R-17

(A) 

Photo

electric

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

mode power

supply 

(Q)

Stepper

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

Graphic Panel

7 inch TFT Color LCD

 Features

7 inch wide screen, TFT Color LCD type 

                                                  Graphic touch panel GP-S070

 Manual

Visit our webwite(www.autonics.com) to download 'GP Editor user manual' or 'GP, LP user manual for communication', 

'GP-S070 user manual'.

● GP Editor user manual

It describes how to write screen data, and is about related usage of GP-S070 HMI function. 

● GP, LP user manual for communication 

It describes connection for external devices such as PLC. 

● GP-S070 user manual

It describes general information on the installation and usage of GP-S070 and system contents. 

● Adopts 7 inch wide TFT LCD for realizing

True Color with 16,777,216 colors

● Analog touch method

: Free tag arrangement than matrix touch method

● Data logger function 

: Supports data gathering and backup of controller

● Supports variable image library 

● Enables to monitor multi station and multi channel at 

the same time 

● Supports several interface 

: Supports USB Host/Device to high speed download and 

manage files 

: Easy to connect various external devices with RS232C 2 ports 

and RS232C/RS422 multi-communication port 

● Supports several fonts: Supports window true type and several bitmap fonts (selectable) 

● Device monitoring function  

: Enables to monitor/control variable of connected control through communication port 

● Easy S/W upgrade at website 

(1) GP firmware file 

(2) GP Editor (drawing program) 

(3) Additional protocol 

(4) Language and font, etc 

● Connects printer/barcode reader: Enables to print out alarm history, to read barcode 

NEW

 Ordering information

Model

Item

Series

Monitor size Display unit

Color

Power supply Interface

GP-S070-T9D6 

Graphic 

panel

S series

7 inch

TFT Color 

LCD

16,777,216 

color

24VDC

RS232C, RS422, USB HOST,

USB DEVICE, Ethernet

GP-S070-T9D7 

RS232C (2EA), USB HOST

USB DEVICE, Ethernet

Please read “Caution for your safety” in operation 

manual before using.

GP-S070

Summary of Contents for GP-S070

Page 1: ...ue Color with 16 777 216 colors Analog touch method Free tag arrangement than matrix touch method Data logger function Supports data gathering and backup of controller Supports variable image library Enables to monitor multi station and multi channel at the same time Supports several interface Supports USB Host Device to high speed download and manage files Easy to connect various external devices...

Page 2: ... for front panel Accessory Fixing bracket 4EA Battery included Approval Unit weight Approx 520g Figure display Line rectangle circle text bitmap Tags Numeral display Displays the designated device as numerical value decimal hexadecimal octal binary real number ASCII display Displays the designated device value as ASCII character Time display Displays current time or date Alarm history Registers al...

Page 3: ...een RS422 or RS232C A USB Device USB Host Ethernet RS422 or RS232C B M4 BOLT Max 4 R3 15 Min 240 Panel thickness Max 4mm 6 5 28 5 134 125 146 Min 175 Mounting slot for bracket Panel cut out Fixing bracket unit mm Dimensions 186 1 1 0 126 1 0 0 Part description Ethernet Port For connecting LAN cable and hub use direct cable and for connecting PC directly use cross cable USB Device It is used to upl...

Page 4: ...t fixing brackets in 4 slots 2 slots is in upper side 2 slots is in lower side Sold separately Transmission cables connectable into external devices such as PLC are sold separately refer to the R 32 page for GP LP communication cable 3 Tighten fixing bracket with M4 Screw driver and tightening torque is 0 3 to 0 5N m ...

Page 5: ... including PC PLC serial printer barcode reader and dedicated connectors can be connected into both RS232C and RS422 ports Device must be set for the port in system setting for LP S044 LP S070 For details refer to GP user manual Use the dedicated communication cable for the each connected device Refer to the GP LP communication cable of R 32 page For the method of wiring external devices of PLC re...

Page 6: ...ated environment of operation and control It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices Setting and change of production process It graphicalizes mechanical control components such as button switch and lamps so that saves cost and space and improves the preservation of devices Convenient setting ...

Page 7: ... SmartStudio programming manual Refer to the manual for details on website www autonics com resources Basic operation flow LP Logic Panel Logic panel is created for integrated panel in most demanding industrial environments that have been consisted of HMI PLC and I O The LP through integration realizes cost down wire reduction space saving and enhanced user friendliness The logic panel perfectly s...

Page 8: ...es Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices Output device Solenoid Lamp Motor Other output devices System configurations Stand alone LP Series Stand alone system in LP series controls a variety of I O without adding other...

Page 9: ...0Ω please use the wire of min 1 25mm dimension Please check the pin number and connect to GP LP communication port Please tighten bolt on terminal block with specified tightening torque When liquid crystal from the broken LCD is smeared on your skin wash it for 15 minutes If it is gotten in your eye wash it for 15 minutes and contact a medical specialist for more information Do not inflow dust or ...

Page 10: ...PU direct connection loader FX1N CPU direct connection loader FX2N CPU direct connection loader FX2NC CPU direct connection loader FX3U CPU direct connection loader MITSUBISHI Q For Cnet unit Q00J Cnet Q00 Cnet Q01 Cnet Q02 Cnet Q02H Cnet Q06H Cnet Q12H Cnet Q25H Cnet NAIS FP FP0 C10 CPU direct connection loader FP0 C14 CPU direct connection loader FP0 C16 CPU direct connection loader FP0 C32 CPU ...

Page 11: ...Connection type GP S057 GP LP S044 GP LP S070 SIEMENS SIMATIC S7 300 CPU312 CPU direct connection loader CPU312C CPU direct connection loader CPU313C CPU direct connection loader CPU313C 2 CPU direct connection loader CPU314 CPU direct connection loader CPU314C 2 CPU direct connection loader CPU315 2 CPU direct connection loader CPU317 2 CPU direct connection loader CPU319 3 CPU direct connection ...

Reviews: