ABL Series
A-50
-|Transparent setting guide|-
Replacing Relay and Using Jumper Bar
1. Replacing relays
1) Remove the protection cover.
2) Push the operation indicator guide in direction to remove the relay.
3) Insert a new relay to the case.
※
1: The color of the jumper bar insertion holes indicate the relay types of the model.
(green: MATSUSHITA (Panasonic) PQ, navy blue: OMRON G6B)
※
Only insert designated relays for each model.
※
Execute above directions only for replacing relays. If not, it may cause relay damage.
ABL-L04PQ/R6-
NPN (+ COM)
PNP (- COM)
LOAD COMMON
Insert the jumper bar to see NPN mark
below terminals 8, 7, 6, 5.
Insert the jumper bar to see PNP mark
below terminals 8, 7, 6, 5.
Insert the jumper bar above
terminals 12, 11, 10, 9.
Remove the protection cover and use the jumper bars accordingly.
2.
Using jumper bars
Rated load current 3A
Rated load current 5A
①
Operation
indicator
guide
Relay type
color
※
1
①
①
1. Using jumper bar
The right figure example is for 4 ABL-L01
- units with jumper bar.
For power common, insert a jumper bar to top. For load common, insert it to bottom.
※
ABL-L01 - model is integrated relay. The unit cannot replace only relay.
ABL-L01TN/PA-
1. Replacing relays
1) Pull the protection cover towards direction
①
.
2) Insert the ejector as proper side to
②
direction and pull it to
③
direction to remove.
3) Insert a new relay to the case.
ABL-L04PA/TN-
※
1: Two way ejector position for relay replacement
Replacing for TAKAMISAWA (Fujitsu) relay
Replacing for MATSUSHITA (Panasonic) relay
Removal and insert TAKAMISAWA (Fujitsu) relay
Removal and insert MATSUSHITA (Panasonic) relay
< Removal >
< Insert >
< Removal >
< Insert >
①
①
②
③
Ejector
※
1
POWER COMMON
LOAD COMMON
NPN (+ COM)
PNP (- COM)
LOAD COMMON
Insert the jumper bar to see NPN mark
below terminals 8, 7, 6, 5.
Insert the jumper bar to see PNP mark
below terminals 8, 7, 6, 5.
Insert the jumper bar above
terminals 12, 11, 10, 9.
Remove the protection cover and use the jumper bars accordingly.
2.
Using jumper bars