background image

ABL Series

A-48

-|Transparent setting guide|-

 Connections

 Rated load current 3A

 ABL-L01PA(TN)-NN(NY)

● ABL-L01PA(TN)-PN(PY)

INPUT

RY1

R1-

R1+

GND

24VDC

OUTPUT

RY1

INPUT

JP2

R1-

R1+

GND

24VDC

OUTPUT

1

1

2

2

3

3

4

4

JP1

JP1

JP2

 parts are only for ABL-L04  -UY (varistor installed type).

 NPN, PNP, LOAD common are operated by the inserting position of the Jumper bar. Please refer to the ‘2. Using jumper bars’ 

of ‘

 Replacing Relay and Using Jumper Bar’. 

 ABL-L04PA(TN)-UN(UY)

NPN common

by jumper bar

LOAD common

by jumper bar

INPUT

OUTPUT

9

PNP common

by jumper bar

GND

RY1

5

+24VDC

13

1

GND

10

RY2

6

+24VDC

14

2

11

GND

RY3

7

+24VDC

15

3

12

GND

RY4

8

+24VDC

16

4

Summary of Contents for ABL Series

Page 1: ...Rail or screw mounting Relay Fujitsu NYP24W K Panasonic APAN3124 PQ1a 24V Omron G6B 1174P FD US 16 point Rated load voltage 3A Relay protection with the cover Easy relay replacement with relay ejector...

Page 2: ...using stranded wire use End Sleeve ferrule terminal crimp terminals 5 In case of ABL L04 Y varistor installed type this is 300VAC 6 The weight includes packaging The weight in parenthesis is for unit...

Page 3: ...ated load current 3A ABL L01TN PA Jumper bar model JB 9 0 04L For the desired application power load common jumper bar is sold separately 4 31 9 27 4 2 2 0 5 1 2 6 12 5 2 ABL L04TN PA Jumper bar model...

Page 4: ...or ABL L04 UY varistor installed type NPN PNP LOAD common are operated by the inserting position of the Jumper bar Please refer to the 2 Using jumper bars of Replacing Relay and Using Jumper Bar Jumpe...

Page 5: ...arts are only for ABL L04 UY varistor installed type NPN PNP LOAD common are operated by the inserting position of the Jumper bar Please refer to the 2 Using jumper bars of Replacing Relay and Using J...

Page 6: ...H16R6 NN ABL H16R6 PN 3 4 1 2 RY1 GND1 24VDC1 24VDC2 GND2 N C1 N C3 R1 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R2 R1 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R2 N C2 N C4 JP1 JP2 JP3...

Page 7: ...indicator guide Relay type color 1 1 Using jumper bar The right figure example is for 4 ABL L01 units with jumper bar For power common insert a jumper bar to top For load common insert it to bottom A...

Page 8: ...cutting V groove Jumper bar Jumper socket part Installation 1 Mounting and removal at DIN rail Mounting 1 Pull the rail lock towards direction 2 Attach the DIN rail connection part onto the DIN rail 3...

Page 9: ...voltage current or Class 2 SELV power supply device 5 Wire as short as possible and keep away from high voltage lines or power lines to prevent surge and inductive noise Do not use near the equipment...

Page 10: ...Series ASL Series Power Relay SSR I O Terminal Blocks Interface Terminal Blocks Common Terminal Blocks Sensor Connector Terminal Blocks Relay Terminal Blocks I O Cables Connector Type Cables Open Typ...

Reviews: