40
SC 600 II
9.
LED indicate
a.
LED of Power indicated the input power.
b.
LED of LEARN indicated the transmitter learn status.
c.
LED 1 indicate the ‘CLOSE’ external button, if the button is pressed the LED will light.
d.
LED 2 indicate the ‘OPEN’ external button, if the button is pressed the LED will light.
e.
LED 3 indicate the ‘STOP’ external button, if the button is pressed the LED will light.
f.
LED 5 indicate the ‘O/S/C’ external button, if the button is pressed the LED will light.
g.
LED 6 indicate the ‘pedestrian switch’ external button, if the button is pressed the LED will light.
h.
LED 7 indicate the ‘infrared sensor’ status, if the output is connected the LED will light.
i.
LED 9 indicate the ‘Loop detector’ status, if the output is connected the LED will light.
j.
LED 10 indicate the ‘Close limit switch’ status, if the switch is connected the LED will light.
k.
LED 12 indicate the ‘Open limit switch’ status, if the switch is connected the LED will light.
10.
Maintenance
Check the door once a month. The door should be carefully checked for balance. The door must be in good working
order.
We suggest for safety reasons, photocells be used on all gates.
Disconnect from mains supply before replacing bulb.
Be sure to read the entire manual before attempting to perform any installation or service to the door operator.
Our company reserves the right to change the design and specification without prior notification.
11.
Troubleshooting
Trouble Possible
causes Solutions
The door fails to open
and close. LED display
does not light.
1. Power is OFF
2. Fuse burn
1. Make sure that power is ON.
2. Replace fuse.
The door can open
fails to close.
1. Infrared beam is
obstructed.
2. Infrared sensor function is
enabling, but the sensor has
not been installed.
1. Remove obstructions.
2. Make sure the infrared sensor
function is disabling.
Remote transmitter
does not work.
1. Battery level may be low
2. Transmitter code is lost
1. Replace the battery inside the
transmitter.
2. Reprogram the transmitter.
The transmitter
operating distance is
too short.
Battery level may be low. Replace
battery.
12. Packing list
After receiving the gate operator, you should make an unpack-inspection, in which you should check whether the product was
damaged. If you have any problem please contact our dealer. You should find the following items in our standard packing:
No. Item
Quantity
1
SL600AC sliding gate
operator
1
3
Release key
2
4
User’s manual
1